Installation and Operating Instructions V01
43
The LCD will switch to standby mode and jump to the home page automatically, and
the backlight will turn off when there is no button operation in 30 seconds.
Object
Description
A
Date&Time
B
Output power
C
Daily energy
D
Total energy
E
Error code*, see chapter 9.3
F
Checking time
G
Operating status:
waiting,
operating,
fault
H
Field area of output power from 4:00 to 22:00
I
Load limit Enable Indication
*The operating temperature of the inverter can’t be lower than -25°C .The inverter
goes into fault mode and stops power generation when the temperature is lower
than -25°C. The LCD will show the error message “Temp. under -25°C”.
9.4.5 Operation information
There are two pages showing the current operating data about the AC&DC sides of
the inverter respectively. Switch between these 2 pages by pressing the “
▲
” or “
▼
”
button.
Running Info
A
▶
B
▶
C
▶
F
▶
E
▶
D
▶
VacL1
V
236.1
VacL2
V
235.5
IacL1
A
8.3
IacL2
A
8.5
VacL3
V
237.8
IacL2
A
8.1
PF
1.00 Phase
Fac
Hz
50.01
Runtime
h
12
Leading
Running Info
G
▶
H
▶
J
▶
I
▶
Vpv1
V
580.8
Vpv2
V
579.2
Ipv1
A
5.1
Ipv2
A
5.3
Ppv1
W Ppv2
W
2896
2798