Installation and Operating Instructions V01
3
2 Safety
2.1 Intended use
1.
Evershine converts the direct current from the PV arrays into grid-compliant
alternating current.
2.
Evershine is suitable for indoor and outdoor use.
3.
Evershine must only be operated with PV arrays (PV modules and cabling) of
protection class II, in accordance with IEC 61730, application class A.
Do not connect any sources of energy other than PV modules to Evershine.
4.
PV modules with a high capacity to ground must be used if their coupling
capacity does not exceed 1.0
μ
F.
5.
When the PV modules are exposed to light, a DC voltage is supplied to this
device.
6.
When designing the PV power plants, ensure that the values comply with the
permitted operating range of all components at all times. The free design
program "Zeverplan" (
http://www.zeverplan.com
) will assist you.
2.2 Safety standards
Evershine complies with the EU Low Voltage Directive 2006/95/EC and the EMC
Directive 2004/108/EC. Evershine also complies with the requirements for safety
and EMC in Australia and New Zealand market.
Evershine labeles with the CE and RCM marks. For more detail information about
certificates in other countries and regions, please visit website
(
http://www.zeversolar.com
).