Page 11
© 2021 CLEMCO INDUSTRIES CORP.
www.clemcoindustries.com
Manual No. 30421
2.3.3
Refer to the table in Figure 8 to determine the
minimum ID of air-supply line to the cabinet and connect
the line from the air source to the air filter. A smaller
diameter hose may reduce blasting efficiency.
MINIMUM COMPRESSED-AIR LINE ID
Jet Size
Air Line Length
1/8"
No. 4
5/32"
No. 5
3/16"
No. 6
25 feet
3/4"
3/4"
1"
50 feet
3/4"
3/4"
1"
75 feet
3/4"
1"
1"
100 feet
3/4"
1"
1"
Figure 8
2.3.4
Connect the air
supply line to the previously
installed air fitting.
Hose disconnection while under pressure can
cause serious injury or death. Use safety lock
pins or safety wire to lock twist-on couplings
together and to prevent accidental separation,
and use safety cables to prevent hose from
whipping should separation occur. Safety lock
pins and safety cables are listed in
Section
10.1: Optional Accessories.
2.4
Ground the Cabinet
and Power Module
2.4.1
To prevent static electricity buildup, attach an
external grounded wire from an earth ground to the
grounding lug on the cabinet and power module.
2.5
Connect Electrical Service
Shorting electrical components can result in
serious injury or death from electrical shock or
equipment damage. Electrical power must be
locked out and tagged out before performing
any electrical work. All electrical work or any
work done inside a control panel or junction
box must be performed by a qualified
electrician and comply with applicable codes.
2.5.1 Standard single-phase wiring
2.5.1.1
Standard Pulsar Plus cabinets are 120-volt
single phase. Power is supplied by a U-ground plug;
plug it into a 120-volt outlet. No additional wiring is
needed; a wiring schematic is stowed inside the
electrical control panel for reference.
Do not use electrical adaptors that eliminate the
ground prong on 120-volt plugs. Doing so can
cause electrical shock and equipment damage.
Figure 9
1/2" NPT Air Filter
Secure safety cable to the power module to prevent it from slipping off.
Air-Supply Hose
Refer to the table in Figure 8.
Air Fitting
Use safety cable to prevent separated hose from whipping.
Once installed, remove all slack from the cable.
Apply thread sealant to male NPT threads
.
The type of air fitting and hose connections are for reference only.
When using twist-on couplings, install safety lock pins to prevent accidental disconnections.
Pneumatic Inlet Assembly