7.10.4
Press the parts together and insert the retaining
clip over the mounting flanges and torque the screws to
1.2 N m (10.6 lbf in).
7.11
Replacing Reclaimer Wear Plate
To access wear-plate mounting screws, the
reclaimer must be removed from the power
module. Pulsar reclaimers weigh about 100 lbs.
When removing and installing the reclaimer, it
must be adequately supported and secured to
appropriate lift equipment. Failure to secure
and use proper lift device can result in injury.
7.11.1 300
cfm
reclaimer
with
welded-on,
nonremovable top ‒ Figure 40
Refer to Section 7.11.2 to replace the wear plate in a
600 cfm reclaimer with a bolt-on, removable top.
Installation Notes:
Make sure an inlet-pipe gasket,
Stock No. 11746, is available to replace a compressed
or damaged gaskets on the reclaimer inlet.
7.11.1.1
Remove the flex hose from the reclaimer inlet.
Figure 40
7.11.1.2
Remove the reclaimer inlet-pipe adaptor,
adaptor gasket, and old wear plate. The wear plate is
held in place by screws attached from the outside of the
Align leading edge and
clamp where needed.
Use board to pry back of wear plate against
reclaimer wall and then install screws.
Screws
Wear Plate
Filter
Mounting Bracket
O-Ring
Retaining Clip
O-Ring
Branch Module
Pilot-Operated
Pressure Regulator
Mounting Screws
Mounting Flanges
Bracket Recess