PULSAR
®
PLUS III-S, III-S6, and VI-S SUCTION BLAST CABINETS
Page 12
© 2021 CLEMCO INDUSTRIES CORP.
www.clemcoindustries.com
Manual No. 30421
2.6
Connect Media Hose and Air Hoses – Figure 10
2.6.1
Refer to Figure 10 and attach the
clear media
hose from under the cabinet hopper to the metering
valve at the bottom of the reclaimer hopper by pushing
the hose onto the barded fitting.
2.6.2
Attach the green air hose from the
BNP Gun
to the compatible fitting on the pneumatic inlet
assembly’s regulator and tighten it securely.
2.6.3
Attach the green air hose from the
blow-off
nozzle to the compatible elbow fitting on the lower side
of the pneumatic inlet assembly and tighten.
2.7
Connect Conveying (flex) Hose
2.7.1
Connect the flex hose to the cabinet-hopper pipe
adaptor and reclaimer inlet adaptor, as shown in Figures
5 and 6. It is easier to slip the hose over the adaptors and
create a tighter seal if the first two or three inches of wire
are removed from the inside of the hose. The wire has
been stripped on hoses supplied on new cabinets. Use
care not to damage the hose. Clamp flex hose securely in
position with worm clamps provided.
NOTE: The hose
wire helps dissipate static electricity in the conveying
hose and helps ground each segment. For the hose
wire to dissipate static electricity, the wire must touch
the metal of each segment.
2.8
Set Air-Inlet Damper ‒ Figure 11
Located on the top-rear edge of the cabinet, as shown in
Figure 5.
2.8.1
The inlet damper must be set to match the
cabinet dimensions and reclaimer size. The decal on the
damper shows the settings in degrees. For the initial
setting, align the handle as follows:
Pulsar III ............................. align handle to 30 degree
Pulsar VI ............................ align handle to 30 degree
2.8.2
Loosen the lock nuts and position the damper
handle as noted. When correctly positioned, tighten the
lock nuts to maintain the setting. Refer to Section 5.10
for adjustment procedure.
Figure 11
Figure 10
Damper Handle
Degrees Label
Align handle to degrees as
noted in Paragraph 2.8.1.
Air-Inlet Damper
BNP Gun
Pneumatic Inlet Assembly
Blow-Off Nozzle
Clear Media Hose
Metering valve
Reclaimer
Hopper Plate
As seen from outside of the cabinet.