Manual No. 30421
the new time is saved, the unit resumes operation with
the new time setting.
TEST
of
f
on
on
OFF TIME
Figure 23
NOTE: Do not adjust ON time. Adjusting ON time will
consume additional air but will not improve cartridge
cleaning. If ON time is accidentally changed, reset it to
factory settings, per Section 5.9.3.
5.9.3 Reset pulse ON time to factory setting, 0.15
seconds (150 milliseconds).
NOTE: There is no need to change ON time. ON time is
factory set for 150 milliseconds (0.15 second), as shown
in Figure 26. If ON time is accidentally changed, reset it
to 150 milliseconds as follows:
NOTE: The numbers shown in Figure 24 signify the
following step numbers:
1. Make sure the ON subrange is set to milliseconds, as
noted in Section 5.9.5.2, Figure 26.
2. Press the right "on/arrow up" button and ON appears
briefly on the display.
3. If the number on the display is above 15, decrease
time by pressing the left "off/arrow down" button until
15 appears.
4. If the number on the display is less than 15, increase
time by pressing the right "on/arrow up" button until
15 appears.
When 15 appears on the display do not press anything;
after a few seconds, the display starts flashing,
indicating the new time is being saved. Once the new
time is saved, the unit resumes operation with the new
time.
on
TEST
of
f
on
ON TIME FACTORY SETTING
Figure 24
5.9.4 Reset timer function to factory "A"
setting
NOTE: There is no need to change the function setting.
If the function is accidentally changed, reset it to the
factory setting as follows:
1. Turn OFF the power switch located on the cabinet
control console.
2. Press and hold down the timer "TEST" button and
Switch ON the power switch.
3. Release the "TEST" button after the current timer
function (A through F) appears on the display.
4. Use the "off/arrow down" or "on/arrow up" buttons to
select function "A".
5. When "A" appears on the display, do not press
anything; after a few seconds, the unit resumes
operation with the "A" function.
5.9.5 Reset timer subranges to factory settings
NOTE: The OFF subrange is factory set for seconds, as
shown in Figure 25. The ON subrange is factory set for
milliseconds. Each value shown on the LED is 10
milliseconds (1/100 of a second), as shown in Figure 26.
There is no need to change subranges; if subranges are
accidentally changed, reset them to factory settings, as
follows:
hrs
min
sec
x10ms
1
2
4
3
LED
Display
hrs
min
sec
x10ms
1
3
2
4
LED
Display