Z 45/75-90/110
44
Cable routing
www.zepro.com
5.5
Control power cable
NOTE!
See also the respective vehicle manufacturer’s electrical instructions.
1.
If the control power cable is not pre-routed, e.g. VDHH, route the control power cable from the driver’s
cab to the lift.
IMPORTANT
!
The cable must be protected with rubber grommets when it passes through beams or bulkheads. Position any quick
connectors so they are well protected from moisture and dirt.
2. Connect the control power cable to the cab switch (CS) on the vehicle instrument panel. Connect to the
on-board electrical system via a 10 A (24 V), 15 A (12 V) fuse according the customer’s wishes. See wiring
diagram in Sections 6.8 and 6.9.
5.6
Warning lighting/
foot controller
If the tail lift is equipped with warning lights and/or
foot controller, their cabling must be routed and con-
nected according to the following description.
1. Connect the supplied cable to the connector on
the cable of the foot control/warning light. Then
route the cables and mount with cable ties ac-
cording to Image 65.
NOTE!
Route the cables between the platform and the
1st boom’s pipe, so they are well protected when
the platform hits the ground.
Leave enough slack to the first cable tie to avoid the
risk of damage to the cable during lift operations.
Image 64. Warning lighting and foot controls
Image 65. Installing cabling