Z 45/75-90/110
Cable routing
39
www.zepro.com
Z45 (110 bar)
5915
12 volt
24 Volt
Pump - Motor unit
95 A
60 A
Magnet (hydraulic unit)
1.4 A
0.7 A
Magnet (electric hose rupture valve)
1.5 A
0.75 A
Solenoid
1.8 A
0.9 A
Minimum recommended conductor cross-sectional area
(copper cables, positive and negative cables)
Control cable
1.5 mm
2
1.5 mm
2
Supply cable, L < 8 m
25 mm
2
25 mm
2
Supply cable, L = 8 - 15 m
35 mm
2
35 mm
2
Supply cable, L > 15 m
-
35 mm
2
Battery
Min. capacity, I
min
140 Ah
110 Ah
Min. voltage during operation, U
min
(at lift)
9 Volt
18 Volt
Image 57. Battery capacity and definition of the length of the earth and main power cables
-
+
-
+
L
L
U
min
I
min
I
min
U
min
5.2
Sizing electrical systems
Ensure that the battery and charger capacity is sufficient for the product in question and that cable with suf
-
ficient cross-sectional area is used.
NOTE!
Make sure the tail lift has access to the minimum recommended current capacity (I
min
)
.
Some vehicle models have restrictions regarding the amount of current the lift can access from the existing
battery. Some vehicle models do not fully charge the battery. It may therefore be necessary to switch to a
battery and sometimes also to a charger with a larger capacity.
NOTE!
Make sure the lift has
access to the minimum
recommended current ca-
pacity (I
min
)
.
Some vehicle
models have restrictions
regarding the amount of
power the lift can access
from the existing battery.