Installation
Test the position of the underrun protection with-
out tightening the bolts to check that the statutory
dimensions are obtained. Adjust if necessary then
tighten the bolts with a torque wrench. See "3.2
Statutory dimensions" on page 10.
1. Hang the four U protection brackets on the lift
frame by inserting the projecting parts into the end
of the fixing profiles.
2. Check that the statutory measurements are
maintained. See "3.2 Statutory dimensions" on
page 10.
3. Fasten the outer brackets with two M12x30 (8.8)
bolts each, including support plate. The bolts are
inserted from inside the frame and outwards.
Remove the frame end plugs so as to reach the
fastening points for the outer brackets. Tightening
torque 90 Nm.
4. Fasten the inner brackets with two M12x30 (8.8)
bolts each. The bolts are inserted from inside the
frame and outwards. There are openings on the
underside of the frame to allow access to the fas-
tening points, right in front of the inner brackets.
Tightening torque 90 Nm.
Image 33. Installing underrun protection
Image 34. Installing underrun protection
max 25 mm
max 25 mm
M12x30 8.8 (90 Nm)
M12x30 8.8 (90 Nm)
Image 35. Installing brackets onto frame.
m
WARNING!
Check carefully that there is no risk of the outer part of
each bracket impacting any part of the cylinders when
using the lift’s functions. In particular, check in relation to
the cylinder hose connections, especially when the outer
part of the brackets is installed a long way in.