Automatic Door Opening (DOORMATIC)
[
disabled
/enabled
]: enables the door/s
to be opened automatically when receiving a call.
•
Initial Status (After Download)
[
Disabled /
Enabled
]: sets whether the
automatic opening is enabled or not after ETS Download. It also can be changed
at runtime through the object
“[VI n] Enable Automatic Door Opening”
.
•
Disable if “Do Not Disturb” Mode Is Active
[
disabled/
enabled
]: disables the
automatic door opening when do not disturb mode is active.
•
Opening Delay
[
0
…255
] [
x 1s
]: set a time after which the automatic door
opening command will be sent.
➢
Enable KNX Objects to Trigger Opening
[
disabled
/enabled
]: enables the 1-bit
object “
[VI n] Trigger Switch n
” which can open the door by writing on the KNX
object. Choosing the
Object Value
[
1 = Open
/ 0 = Open
] that will open the door is
possible.
Important: For safety reasons, it is recommended not to use this communication
object or to use it under the responsibility of the integrator.
Door n
[
disabled
/enabled
]: enables or disables every door, up to 4 for each outdoor unit.
Note:
the door concept in Z70 v2 refers to the switches configured in GetFace IP in
section
Hardware
Switches.
➢
Label
: name that will appear on the preview, incoming call and ongoing call panel
to identify the door.
➢
HTTP Command Opening
[
disabled/
enabled
]: set whether the HTTP command is
sent when the door is opened.
➢
Automatic Door Opening (DOORMATIC)
[
disabled
/enabled
]: defines whether
each of the doors should open automatically with the set delay. Its selection will be
available whenever the general parameter for
automatic door opening
of the
outdoor unit is enabled.
For further information about the configuration above parameters of external units GetFace IP,
please refer to the “
Z41 COM / Z70 + GetFace IP Configuration Guide
” and the specific
docume
ntation of “
Zennio GetFace IP
.