background image

 

 

   Touch-MyDesign

 

http://www.zennio.com

                                                      

Technical Support:

 

http://zennioenglish.zendesk.com

 

 

 

 

 

 

 

 

 

 

 

 

Figure 4 

Touch panel (6-button model)

 

 

As 

Figure 4

 shows, two areas can be distinguished in the touch panel: 

 

The main buttons

, grouped in pairs, all over most of the touch panel surface. 

 

The additional buttons

, as an aligned panel, separate from the main buttons. 

All the main buttons are identical, and also every additional button is identical to the 

others, which makes it possible to configure all of them for user-defined applications. 

Each of the mentioned buttons incorporates a central LED which, by default, will turn 

on for a brief instant whenever the button is touched, although alternative LED 

behaviours may be configured for every button, depending on the parameterized 

function: 

 

Regular lighting

: the LED will light for only an instant after the button is 

touched. LEDs behave this way by default. 

 

State-dependent lighting

: the LED will or will not light depending on the 

value of the communication  object  that corresponds to the function 

implemented by the button. The exact relation between the different values of 

Pair A 

Pair B 

Pair C 

Main  

Buttons  

Additional 

Buttons 

Содержание Touch-MyDesign Display One

Страница 1: ...KNX Capacitive Touch Switch with 4 6 8 buttons ZN1VI TPTMD4 ZN1VI TPTMD6 USER MANUAL ZN1VI TPTMD8 Application Program Version 1 0 User Manual Version 1 0 _a www zennio com...

Страница 2: ...Parameterization 10 3 2 General 11 3 3 Main Buttons 18 3 3 1 Pair 20 3 3 2 Individual 23 3 4 Additional Buttons 27 3 4 1 Disabled 28 3 4 2 Setpoint Temperature 29 3 4 3 1 byte Control unsigned int 29...

Страница 3: ...functions is enhanced by the built in analogue digital inputs temperature sensor and thermostat function and by an elegant and fully customizable design of the front glass consumers can choose the bu...

Страница 4: ...ome Back object binary or scene which will be sent to the bus on the first press of the touch panel after a long standby period Two analogue digital inputs for movement sensors temperature probes addi...

Страница 5: ...wer supply since it is powered through the KNX bus Figure 3 Touch MyDesign Element diagram The programming button 5 shown in Figure 3 may be pressed with the help of a thin screw to set Touch MyDesign...

Страница 6: ...gain making sure that the front glass is not touched during this process For detailed information about the technical features of Touch MyDesign as well as information on security and on the installat...

Страница 7: ...upled inputs each of which may be independently configured as a switch sensor a push button a movement detector or a temperature probe And depending on the selection a series of external elements may...

Страница 8: ...f them for user defined applications Each of the mentioned buttons incorporates a central LED which by default will turn on for a brief instant whenever the button is touched although alternative LED...

Страница 9: ...air of buttons The only difference compared to the previous case is that under the both LEDs case the two LEDs will always turn off or on simultaneously as if it were a unique state indicator consisti...

Страница 10: ...meterization starts Figure 5 shows the communication objects displayed by default General Scene receive intended for the reception of scene values from the bus General Scene send destined to send scen...

Страница 11: ...rizontal vertical of the device with the aim of implementing a logical behaviour in the buttons Figure 7 Orientation of the device Next to Touch MyDesign Orientation a second parameter is shown Pair b...

Страница 12: ...rtain general attributes that will affect all the LEDs For that purpose this parameter provides two options Default the LEDs will assume the default light levels for the on and off states maximum leve...

Страница 13: ...ght mode implements by itself an additional attenuation of the light levels Figure 8 Lighting with the night mode and the flash object enabled Night mode permits enabling Yes or disabling No the funct...

Страница 14: ...n the max light level in the night mode Even the min light level in the normal mode will be Note due to hardware reconfiguration switching from one mode to the other causes that for 2 3 seconds the to...

Страница 15: ...in seconds how much time the device must stay idle since the last button touch before entering into the locked state Unlocking method defines the procedure for leaving the locked state of the touch p...

Страница 16: ...welcome back object is effectively sent Note if combining the welcome back function with the automatic timed touch lock function it is important to take into account that the delay of the sending of t...

Страница 17: ...this parameter will bring up a new object Internal sensor Current temperature as well as a new parameterizable window see Figure 11 from where it is possible to define the following Figure 11 Internal...

Страница 18: ...ing which will send the value 1 as soon as the temperature reaches the limit corresponding to each case and the 0 as soon as such situation ends It is therefore necessary to define the limit temperatu...

Страница 19: ...led In short the following functions are available for the main buttons depending on the behaviour Disabled Pair or Individual parameterized for each pair of buttons Disabled non functional buttons in...

Страница 20: ...nary control object through which the values 0 or 1 will be sent to the KNX bus depending on user touches over the buttons of the pair The particular correspondence between each button in the pair and...

Страница 21: ...f the light source according to Table 2 Dimming step Number of presses required for the entire dimming 0 100 1 100 1 2 50 2 3 25 4 4 12 5 8 5 6 25 16 6 3 1 32 7 1 5 64 Table 2 Step dimming Pair button...

Страница 22: ...value of the X Light On Off object therefore behaving as a state indicator However in this case both LEDs will always share the same light status i e switching on and off together Shutter this option...

Страница 23: ...d for the former which permits the following options Disabled this option disabled by default entirely disables the functionality of button Xi however there will still be the possibility of selecting...

Страница 24: ...that corresponds to the button has the value 1 the LED will light with the maximum power level Whenever the object that corresponds to the button has the value 0 the LED will light with the minimum po...

Страница 25: ...will then turn off again according to the custom OFF level if parameterized State dependent the light state of the LED will depend on the current value of the Xi 1 byte value unsigned int object so i...

Страница 26: ...tton and two communication objects Xi Light On Off Toggle 1 bit linked to short touches and Xi Light dimming Toggle 4 bit linked to long touches Having only one button to perform these functions impli...

Страница 27: ...er short touch on the button will cause the sending of an upwards step order 0 through the same object After that a further short touch will cause the sending of the value 1 again and so on for the ne...

Страница 28: ...dividual buttons permits configuring each of the additional buttons as an independent control analogously as with any of the main buttons while all the other options are intended to jointly parameteri...

Страница 29: ...re setpoint additional buttons This type of functionality will always entail a state dependent behaviour in the LEDs as soon as the Z Temperature setpoint object receives a value that equals one of th...

Страница 30: ...00 depending on the particular button being touched Figure 18 1 byte control scaling additional buttons This type of functionality will always entail a state dependent behaviour in the LEDs as soon as...

Страница 31: ...Touch MyDesign 8 the main buttons are referred to as A1 A2 B1 B2 etc In the case of the additional button panel the 5 buttons constitute a sole block Z because of which the additional individual touc...

Страница 32: ...e LED will switch to the on state default or customized see LED lighting in Section 3 2 when the Zi LED On Off object receives the value 0 and will switch to the off state default or customized when i...

Страница 33: ...will require the definition of the actions to be performed on the event of button presses both short and or long Figure 22 Push button inputs The available options are Short press permits selecting an...

Страница 34: ...ns are Move shutter up the value 0 will be sent Move shutter down the value 1 will be sent Move shutter toggle direction after the first press the value 1 will be sent while after the second press the...

Страница 35: ...after the second press the value 0 will be sent and so on after any subsequent presses commuting the value every time Increase light Stop dimming Toggle after the first press the bus will be sent an o...

Страница 36: ...o please refer to its description for further information Threshold time defines the minimum time in tenths of a second that the push button connected to the input of Touch MyDesign should remain hold...

Страница 37: ...rising edge in the line which takes place whenever the switch closes the circuit No action no action is triggered Send 0 the value 0 is sent through the Ix Edge binary control object Send 1 the value...

Страница 38: ...onding input by sending the values 1 or 0 respectively While the input remains locked any order it sends will be ignored Sending of status 0 and 1 on bus voltage recovery when this option is enabled t...

Страница 39: ...ature so when the difference between two consecutive measurements is greater than such margin the bus will be automatically sent the newest value through the Ix Current temperature object even if no p...

Страница 40: ...h provides up to two detection channels Figure 29 Movement detector inputs Enabling each of the two available channels will bring up a new parameter window as in Figure 30 Figure 30 Channel 1 inputs m...

Страница 41: ...bled from he General tab Once this function has been enabled a set of additional tabs is displayed among them the Configuration window as shown by Figure 31 so that it can be parameterized For detaile...

Страница 42: ...O R T 0 15 0 Last A2 Light Dimming Toggle 4 bit dimming control 7 9 2 Bytes O R T Ac to param Ac to param Ac to param Accord to param 10 4 bits O R T 0 15 0 Last B1 Light Dimming Toggle 4 bit dimming...

Страница 43: ...41 2 Bytes O R T Ac to param Ac to param Ac to param Accord to param 42 4 bits O R T 0 15 0 Last Z3 Light Dimming Toggle 4 bit dimming control 43 45 2 Bytes O R T Ac to param Ac to param Ac to param A...

Страница 44: ...1 Last General Buzzer Enabling 1 Enabled 0 Disabled THERMOSTAT 62 2 bytes I W 40 C 150 C 25 C Last T Temperature Source 1 External Sensor Measure 63 2 bytes I W 40 C 150 C 25 C Last T Temperature Sour...

Страница 45: ...Last T Setpoint Offset Status Current setpoint offset 78 1 bit I W 0 1 0 Last T Setpoint Reset Reset setpoint to default 79 1 bit I W 0 1 0 Irrelevant T Mode 0 Cool 1 Heat 80 1 bit O T R 0 1 Ac to pa...

Страница 46: ...102 1 Byte O T R 128 191 Irrelevant Irrelevant Ix Long Press Save Scene Save Scene Send of 128 191 103 104 2 Bytes O T R 20 95 C 25 C Last Ix Current Temperature Temperature sensor value 106 107 1 bit...

Страница 47: ...35 1 Byte O T 0 63 128 191 Irrelevant Irrelevant Ix Ch y Scene Sending 0 63 Send Scene 1 64 INTERNAL SENSOR 105 2 Bytes O T R 20 95 C 25 C Last Internal Sensor Current Temperature Temperature sensor v...

Страница 48: ...your inquiries about Zennio devices http zennioenglish zendesk com Zennio Avance y Tecnolog a S L C R o Jarama 132 Nave P 8 11 45007 Toledo Spain Tel 34 925 232 002 Fax 34 925 337 310 www zennio com...

Отзывы: