Touch-MyDesign
Technical Support:
http://zennioenglish.zendesk.com
17
enabling and disabling, by object, any audible indication generated by the buzzer,
including those due to the sending of a “1” through “[General] Buzzer”). By
default, beeping is enabled both by parameter and by object. However, even
being enabled by parameter, it is also possible to define (through the “Initial
status (after programming)” parameter) the desired initial state of the “[General]
Buzzer enabling” object. Note, however, that if the buzzer is disabled by
parameter, the two objects related to this function will disappear, which will make
it impossible to enable it afterwards.
Internal temperature sensor
: enabling (“Yes”) this parameter will bring up a
new object (“[Internal sensor] Current temperature”), as well as a new
parameterizable window (see
), from where it is possible to define the
following:
Figure 11
Internal temperature sensor (General)
Temperature sensor calibration:
this option permits implementing a
correction (by adding or subtracting some tenths of a degree) to the
measured temperature in case of a deviation between it and the real
temperature in the room. The allowed values are [-50, 50], i.e., from -5 to 5
ºC.
Temperature sending period
: permits performing a cyclical sending of the
temperature value to the KNX bus through the corresponding object. This
parameter is intended to define the desired cycle time, between 1 and 100
tens of a second. The value “0” will turn off the cyclical sending.
Example
:
to have the temperature of the internal sensor sent every 30
seconds, this parameter should be set to “3”.