7.11. Error messages
The
ZLT
provides users with indications whereby potential faults can be prevented or assessed.
Messages are then alternated with the water temperature:
Message
Cell
flashes
Description
Resolution
E0
Orange
Internal error (com-
munication fault be-
tween the two integrat-
ed cards)
Check the connection of the canvas between the
2 cards, inside the cell
E1
Light blue Internal overheating
(>85°C)
Allow the cell to cool down or install the cell in
a cooler place
E2
Violet
Water
temperature
measurement error
Check the connection of the temperature sensor
inside the cell
E5
Red
Excessively low cur-
rent/lack of salt
Check the salt rate
Remove scale from the cell using diluted acid
Add salt after the requirement has been con-
firmed.
Refer to the section on electrolysis.
This fault can easily result in the punctual pres-
ence of air in the cell, after the filtration pump has
been unprimed or air has entered the circuit.
E6
Blue
Excessively high cur-
rent/too much salt
Check the salt rate
Renew the water part.
Refer to the section on electrolysis.
7.12. Factory reset
It may be necessary to reset the
ZLT
. To do so:
1. Cut the power of the electrolyser via the ON/OFF button present on the power box.
2. Wait for about 30 seconds,
3. Press the button
and keep it held down,
4. Turn the electrolyser back on via the ON/OFF button on the power box.
5. Wait for the cell to display the start-up colors,
6. Release the button
,
7. You will see that
88
is displayed and the colors will again be shown in the cell, which confirms
that the device has been reset to factory defaults.