ZELIA ZLT
5
the less possible scale formation on the cell (commitment of production quality and longevity of
the material).
4.2. Presentation of the ZLT
CCEI has developed light electrolysis. ZELIA's compact and light salt electrolyser is fitted with
a transparent cell whose color varies according to the salinity and water temperature of the pool
(patented method).
When users open their technical room, they know the status of their treatment device straight away
and are assured about the water quality:
• Production in shut down mode, color according to the water temperature
• Production in operating mode, color according to the salinity.
Efficient and optimum production - according to water temperature - reduced when the automatic
cover is closed - 8 production modes
Compact and resistant monobloc cell - fitted with complete titanium plates.
Compact to fit into the most confined technical rooms.
Self-cleaning cell by polarity reversal.
Increased safety by in-built flow detection.
Is assembled in just a few minutes, easy connection with connector.
Specially adapted to underground technical rooms.
In temperature controlled mode, the production period is adapted
according to the temperature
.
5. Installation
5.1. Hydraulic installation
The
ZLT
is installed on a conduit with a diameter of 50mm, using the provided union fittings. It is
installed subsequent to filtration (after the filter). It can be placed both horizontally and vertically.
A bypass installation is favored (essential beyond 22m3/h) so that the flow in the cell can be con-
trolled and the cell can be dismounted without interrupting the filtration.