![ZELIA ZLT Series Скачать руководство пользователя страница 33](http://html1.mh-extra.com/html/zelia/zlt-series/zlt-series_technical-instructions_3318547033.webp)
Technical instructions
ZELIA ZLT
13
Program
Description
Comments
P1
Production 1 hour/day
P2
Production 2 hours/day
P3
Production 4 hours/day
P4
Production 8 hours/day
P5
Production 12 hours/day
P6
temperature controlled production
(1 - 4 hours/day)
Production increases automatically with
water temperature
P7
temperature controlled production
(2 - 12 hours/day)
P8
"Shock" production
Electrolysis works for 24 hours (if filtra-
tion is in progress) and returns to the pre-
vious program
P9
Permanent production
Electrolysis works permanently (when fil-
tration is in progress)
PA
Externally controlled production.
Requires the use of a regulator (see
7.7)
Electrolysis works when the Redox ana-
lyzer dry contact is activated (and if filtra-
tion is in progress)
In the event of power cut, the chosen program will be saved, but it will be staggered.
Once the program is validated, it is recalled alternately with the water temperature.
7.4. Temperature control
In modes
P6
and
P7
ZLT
automatically adjusts the chlorine production period according to the
water temperature. Users can choose between two temperature controlled modes:
• The first (
P6
) is for an "economical" production, specially adapted to small-sized tanks. The
production time will be between 1 and 4 hours per day.
• The second (
P7
) is for a production time between 2 and 12 hours per day.
The production time changes proportionally to the water temperature when this temperature varies:
Program
15°C
17°C
20°C
22°C
25°C
30°C
P6
1 hour
2 hours
2 hours
3 hours
3 hours
4 hours
P7
2 hours
3 hours + 1/2 6 hours + 1/2 8 hours + 1/2 11 hours +
1/2
12 hours