![ZELIA ZLT Series Скачать руководство пользователя страница 32](http://html1.mh-extra.com/html/zelia/zlt-series/zlt-series_technical-instructions_3318547032.webp)
Technical instructions
ZELIA ZLT
12
Item
Description
Indicator
"PRODUCTION"
Off if the production is not in operating mode
Flashing if the production is in standby mode, or if the cycle has ended,
before the next cycle
Permanently on if production is in progress
Indicator
"FLOW"
Off if the flow is not detected
Flashing if the flow detection is in progress (delay)
Permanently on if the flow is detected
Indicator
"COVER"/"REDOX STATUS"
Off if the cover is open (or if the Redox analyzer dry contact is open)
Flashing if detection is in progress (delay)
Permanently on if the cover is closed (or if the Redox analyzer dry contact
is closed)
Button
"TOP/MORE"
Makes it possible to increase, move up the display of parameters or pro-
grams
Button
"BOTTOM/LESS"
Makes it possible to decrease, move down the display of parameters or
programs
Button
"VALIDATION/OK"
Makes it possible to validate the choice of a program
7.3. Choice of a program
The program is chosen after pressing the
button . Users have 5 seconds to select the desired
program (the program flashes during this time) using the buttons
and
.
10 different programs can be selected. Once the program is selected, press the
button again
to validate the selection. To stop the function, all you have to do is press this button again.
OF
is
displayed during deactivation.