Connecting the pressure line
• The pressure outlet of the ZP SPEEDCONTROL has to be
preferably provided with a flat-sealing connecting coupling.
That way, the pump can be easily mounted and dismounted
later (e.g. for maintenance purposes).
• The inside diameter of the pressure line must be at least ¾“
• Seal the construction-side pressure line and connect it with the
connecting coupling of the pressure socket
Softening
equipment
Softening
equipment
ZP SPEEDCONTROL COMFORT
en
English
It is recommended to use a block fi tting on the pressure-side for maintenance and
service purposes.
i
5.4.1 Note on installation of the membrane expansion tank
!
No check valve or pressure reducer may be built in between the membrane
expansion tank and the ZP SPEEDCONTROL COMFORT.
5.4 Pressure line
In case of an application as water supply or pressure boost with automatic switch-
off , a membrane expansion tank according to DIN 4807-5 must be provided. The
membrane expansion tank is absolutely necessary for the function of the frequency
control. No consumers may be built in between pump and membrane.
!