3
For the installer - 23 - EN
Additional programme values
Submenu
Description
Minimum
Maximum
Default
P59
Confi rming the presence of
an enthalpy exchanger
• 0; Enthalpy exchanger fi tted
• 1;
Enthalpy exchanger with RH
sensor.
• 2;
Enthalpy exchanger without RH
sensor.
0 (= No)
2 (= Yes)
0
Note:
If an enthalpy exchanger without a sensor is selected, then the enthalpy programme
will not be activated and malfunction alerts EA1 & EA2 will never occur.
Menu P6 Setting additional programmes
Additional programme values
Submenu
Description
Minimum
Maximum
Default
P60
Confi rming the presence of
a geothermal heat exchanger.
• 0;
Geothermal heat exchanger not
fi tted
• 1;
Geothermal heat exchanger
fi tted
• 3;
Geothermal heat exchanger
unregulated.
0 (= No)
3 (= Yes)
0
Note:
If a valveless geothermal heat exchanger is fi tted, then the unregulated setting must
be selected so that the ComfoAir's bypass valve continues to function properly.
P61
Setting the percentage by which the
supply fan must increase its speed
when the valve of the geothermal heat
exchanger is opened.
0%
99%
0%
P62
Tge (Tgeothermal heat exchanger),
low
0
o
C
15
o
C
7
o
C
P63
Tge (Tgeothermal heat exchanger),
high
10
o
C
25
o
C
23
o
C
P64
Tah (Tafterheater), desired
5
o
C
40
o
C
18
o
C
Menu P7 Reading malfunctions (and system information)
(Malfunction) information values
Submenu
Description
Minimum
Maximum
Default
P70
Current software version.
Version number of the software (without “v”)
P71
Most recent malfunction.
Code in accordance with alarm and malfunction
alert
P72
Malfunction before the most re-
cent one
Code in accordance with alarm and malfunction
alert
P73
Malfunction before the most re-
cent two
Code in accordance with alarm and malfunction
alert
P74
Resetting a malfunction in the
ComfoAir
0
1
0