3
EN - 20 - For the installer
3.7
Commissioning the ComfoAir
After installation, the ComfoAir must be commis-
sioned.
This can be done via the P menus on the digital op-
erating device. These P menus can be used to enter
various settings (ventilation programmes, in partic-
ular) for the ComfoAir. An overview of the available
P menus is given below:
Menu
Options
P1
Reading statuses (from menu P2)
P2
Setting time delays
P3
Setting the ventilation levels
P4
Reading the temperatures
P5
Setting additional programmes
P6
Setting additional programmes
P7
Reading and resetting malfunctions (and
system information)
P8
Setting 0-10V inputs
P9
Reading statuses (from menu P5)
P menus P1, P2 and P9 can be accessed by the
user, mainly to read statuses and set time delays.
The remaining P menus P3 to P8 are intended
sole-
ly
for the installer.
The ComfoAir's bypass valve will not work
for the
fi
rst 4 minutes after a power cut un-
less the programme mode is activated.
3.7.1 CC Ease panel
Accessing the P menus
1
Press
"
" and "
" simultaneously.
2
Wait
until the "P menu" appears on the display.
P menus P1, P2 and P9 can now be
accessed
.
3
Press
and hold "
" and "
" for 2 sec-
onds, simultaneously.
4
Wait
until “P menu” P3 appears on the
display.
P menus P3 to P8 can now be accessed
.
5
Select
using "
" or "
" the desired
e.g., P menu “ 5 ”.
6
Press
"
" to confi rm the P menu.
7
Select
using "
" or "
" the desired
e.g., P sub-menu “ 51 ”.
8
Press
"
" to confi rm the P sub-menu.
Entering settings in P menus
The minimum and maximum values for the
available settings parameters are preset in
the software.
9
Select
a value for the parameter using "
"
or "
".
10
Press
"
" to confi rm.
11
Repeat
steps 5 to 10, to set multiple parameters
in succession.
Or
Press
"
" to return to the P menu.
Returning to the main menu
12
Press
"
" twice.
Содержание ComfoAir 550 Luxe
Страница 1: ...ComfoAir 550 Luxe Manual...
Страница 47: ...1 43...