1.1K~3.3KTL-G3
User manual
- 50 -
3.Soft Version
10.Safety Paras
4.Hard Version
11.MPPT Scan
5.Country
12.Power Ratio
6.Modbus Address
7.Input Mode
The user enters the main menu by long pressing the button, short press and
turns the page to select menu contents, then long press the button to enter "3.
SystemInfo". Turning the page down can select the system information to view.
(D)
Display Time
Long press the button and short press the button to turn the page in the
standard user interface to enter into “4.Display Time”,then long press the button to
display the current system time.
(E)
Software Update
User can update software by USB flash drive , Our company will provide the
new update software called firmware for user if it is necessary,The user needs to
copy the upgrade file to the USB flash drive.
6.4.
Update Software online
1.1K~3.3KTL-G3 inverters offer software upgrade via usb flash drive to
maximize inverter performance and avoid inverter operation error caused by
software bugs.
Procedure:
Step 1
First,turn off the DC and AC breaker,and then remove the
communication waterproof cover as the following picture.If the RS485 line has
been connected,Be sure to release the waterproof nut,Make sure the communication
line is no longer the force. Then remove the waterproof cover,In order to avoid
loosening the communication plug which has been connected.
Figure 6-1