Append Battery Scan:
This option allows one battery reading to be appended to the data being
transmitted. If the DAA H-2221 GOES Radio is being used, the lowest battery reading of either
a current battery measurement or the battery reading during the previous transmission (of the
loaded battery) will be used. Otherwise, the battery value is retrieved just prior to transmission.
Normal applications transmit 15 minute data yet battery values are generally not required that
often. Fifteen minute battery readings also take up transmit time that could be used for other data
values. Selecting ‘Yes’ to this option allows the user to still get a battery value for each
transmission, while shortening the transmit time and allowing other data values to be transmitted
instead.
Redundant Data Sets:
Defines the number of extra data sets to send with each transmission. A
data set is defined as the data collected between transmissions. Setting this option to 0 would
cause the next transmission to contain only data collected since the last transmission. The default
value is 1, indicating that one set of extra or redundant data will be sent along with the new data.
The new data would be the data collected since the last transmission and the extra data set(s)
would be the data collected between the older transmissions in logical order. Sending redundant
data is a common practice with the GOES system, and allows the same data to be transmitted
more than once, protecting against lost transmissions.
Center Data:
Defines whether the transmitted data is centered within the transmission window.
The default is to not center the data, which means the transmission will start at the beginning of
the window. If set to center the data in the window, the System 5000
will calculate
TM
approximately how long it would take to transmit the selected data and delay the start of the
transmission to center the data in the middle of the window. If enabled, the centering process is
done automatically, and the user should not add any time to the Transmit Time option in an
attempt to center the data.
6-16 Outputs
System 5000
TM
Содержание WaterLog Series
Страница 1: ...Model System 5000TM Owner s Manual Revision 1 4 2...
Страница 2: ......
Страница 8: ......
Страница 24: ...2 10 Hardware Overview System 5000TM...
Страница 58: ...5 14 Inputs System 5000TM...
Страница 128: ...10 14 System Setup General Setup System 5000TM...
Страница 144: ...12 6 System Setup Inputs Outputs System 5000TM...
Страница 168: ...14 4 Maintenance and Troubleshooting System 5000TM...
Страница 170: ...A 2 System 5000 Specifications System 5000TM...
Страница 172: ...B 2 Pressure Sensor Option Module Specifications System 5000TM...
Страница 174: ...C 2 Analog Digital Option Module Specifications System 5000TM...