![YSI WaterLog Series Скачать руководство пользователя страница 134](http://html1.mh-extra.com/html/ysi/waterlog-series/waterlog-series_owners-manual_3690995134.webp)
Network Setup
The Network Setup screen allows simple network settings to be defined allowing network
connectivity using the Ethernet port on the front panel. The port can be set up automatically via
the network or entered manually. For examples on how to connect directly to the System 5000
TM
using a PC, please refer to Chapter 13.
Ethernet:
Determines whether the Ethernet port is powered on or off. The port will only be
enabled when the System 5000 is not in a low-power sleep. To have the Ethernet port always
TM
remain on, the System Timeout within System Settings will need to be set to the (None) option.
The System 5000
will use more power in this mode but will be able to respond to any
TM
incoming connections. The Ethernet mode may also be set to Server (DHCP) to allow the
System 5000
to act as a DHCP server, assigning IP addresses to any connected systems. This
TM
mode can be useful when connecting a computer directly to the System 5000
, however should
TM
not be used when connected to a network with another DHCP server.
IP Type:
Specifies how the IP address will be set on the system. The IP Address is a unique
identification on a given network. If a DHCP server (e.g. a router) is running on the network, the
Auto option allows the Update button to automatically retrieve and set the System 5000
’s IP
TM
address, subnet mask, and default gateway. If a static IP is needed (i.e. no DHCP server is
available or a specific IP is desired), the Manual radio button can be pressed to allow manual
entries into the IP address, subnet mask, and default gateway parameters. For proper settings to
allow connecting directly to a PC using the Ethernet port, see Chapter 13.
DNS (Nameservers):
Specifies how the DNS (Nameservers) will be set up. Nameservers allow
the System 5000
to properly communicate with other devices on the same network. Similar to
TM
IP Type, if a DHCP server is available, the Auto option can be used to dynamically retrieve the
DNS information. If manual entries are desired, the Manual radio button can be pressed and two
DNS entries can be entered.
11-6 System Setup - Communications
System 5000
TM
Содержание WaterLog Series
Страница 1: ...Model System 5000TM Owner s Manual Revision 1 4 2...
Страница 2: ......
Страница 8: ......
Страница 24: ...2 10 Hardware Overview System 5000TM...
Страница 58: ...5 14 Inputs System 5000TM...
Страница 128: ...10 14 System Setup General Setup System 5000TM...
Страница 144: ...12 6 System Setup Inputs Outputs System 5000TM...
Страница 168: ...14 4 Maintenance and Troubleshooting System 5000TM...
Страница 170: ...A 2 System 5000 Specifications System 5000TM...
Страница 172: ...B 2 Pressure Sensor Option Module Specifications System 5000TM...
Страница 174: ...C 2 Analog Digital Option Module Specifications System 5000TM...