<1. OVERVIEW>
1-1
IM 12E01B30-02EN 2nd Edition : June 09 , 2021-00
1. OVERVIEW
To keep good quality in industrial or drinking water and rivers or streams, “Turbidity” is one of the
important measurement parameters to control water quality.
Turbidity analyzer is more than ever demanded not only for water treatment, but currently for
measurement/detection of suspended substances in industrial waste or of turbidity at chemical
processing facility.
Since their sales began in 1959, Yokogawa turbidimeters have been continuously developed and
improved using various measurement principles suited for various applications. With its many
achievements, Yokogawa has earned its customers’ confidence. Right Angle Scattered Light
Turbidity Analyzer, composed of Turbidity Detector TB820D and Liquid Analyzer FLXA402T, is
a next-generation analyzer, developed based on years of experience, combining the reliable
measurement principle with our latest digital sensor technology realizing high efficiency in facility
operations.
FLXA402T is a converter designed, being tailored from the well-received FLXA402, to provide
multiple detector measurements. In addition to conventional analog output, Modbus TCP,
Modbus RTU/RS485 are available.
The technology of predictive maintenance prevents accidental shutdown of the factory and
reduces OPEX. TB820D has drastically improved maintainability and minimized maintenance
time.
1.1
Measurement system and structure
TB820D is used with FLXA402T Liquid Analyzer for Turbidity and Chlorine. TB820D also can be
used with a sampling system to control the pressure or flow rate of samples.
l
TB820D Right Angle Scattered Light Turbidity Detector
TB820D measures turbidity. The Detection unit consists of the following three parts.
● Flow cell:
Sample flows through it.
● Detection unit:
Optical system incorporating Light source and Receiver
● Smart unit:
Memory of parameters, the control unit
l
FLXA402T Liquid Analyzer for Turbidity and Chlorine (converter)
The FLXA402T Liquid Analyzer for Turbidity and Chlorine output/displays measurement or status
of connected detectors.
Refer to
for the setup of the display, input/output, or communication.
l
Sampling System
Sample introduced into TB820D needs to be free from air bubbles by using a Head tank to
stabilize the pressure in piping and the flow rate. Use the sampling system if necessary.