<4. Installation>
4-3
IM 01W03D02-01EN
Bracket fastening bolt
FN 310
fastening bolt
U-bolt nut
Spring washer
Bracket fastening nut
2-inch pipe
U-bolt
FN 310
mounting bracket
F0405.ai
Figure 4.5
Horizontal Pipe Mounting
To install FN310 on a 50A (2-inch) pipe, follow
the procedure below.
1. Assemble the FN310 mounting bracket.
2. Install FN310 to the mounting bracket using
provided bolt (4) with a torque 1.4 N•m.
3. Install FN310 mounting bracket to the 2-inch
pipe by U-bolt.