5-16
IM CW500-01EN
Harmonic Analysis Settings
THD calculation
Select the THD (total harmonic distortion) calculation method. Select
THD-F to calculate the total harmonics distortion based on the
fundamental waveform and “THD-R” to calculate based on all rms values.
Settings
THD-F (fundamental waveform as reference)
*
/THD-R
(all rms values as reference)
* Default value
<Procedure>
Use the up and down arrow keys to move to THD calc.
→
Press ENTER
to show a pull-down menu.
→
Use the up and down arrow keys to select
the calculation method.
→
Press ENTER to confirm or ESC to cancel.
MAX hold
If MAX hold is set to ON, the maximum percentage content from the start
of measurement is marked on the harmonics graph.
Settings
ON
*
/OFF
* Default value
<Procedure>
Use the up and down arrow keys to move to MAX hold.
→
Press ENTER
to show a pull-down menu.
→
Use the up and down arrow keys to select
ON or OFF.
→
Press ENTER to confirm or ESC to cancel.
5.3 Measurement Setup