6-12
IM CW500-01EN
Instantaneous Value (W)
Press F1 (W) to show instantaneous values on the screen. For details,
see section 6.1, “Instantaneous Value (W).”
Shifts in Specific Period
Display Items
Remaining time
(time left)
Demand interval is counted down.
DEM P
The present value as a percentage of the target value.
Present value
Target value
is displayed.
DEM G
The estimated value as a percentage of the target value.
Estimated value
Target value
is displayed.
Interval
Saved point
Estimated value
Demand value
(Present)
Target value
Time left
Inspection
cycle
Inspection
cycle
Inspection
cycle
A warning buzzer sounds
when the estimated value
exceeds the target value
after the inspection cycles
have been completed.
6.3 Demand