5-132
<5. Functions of CQ1 Software>
IM 80J01A01-01E
Group
Method Name
Description
Labeling
DivideEachRegion
Attach the same label on adjacent axis
EndPointLabeling
Attach label on endpoint of center line
JuncPointLabeling
Attach label on junction point of center line
LineLabeling
Attach label on center line
LabelTransform
DilateRegion
Dilate labeled region
ErodeRegion
Erode labeled region
SubRegion
Subtract labeled region
AndRegion
Obtain cross union of labeled region
ExpandRegion3D
Expand labeled region within the specified
range
OrExpandRegion3D
Expand after obtaining the union of
labeled region and specified range
ExpandImage3D
Expand labeled region within the specified
range gradually
OrExpandImage3D
Expand after obtaining the union of
labeled region and specified range
gradually
FillUp
Fill up holes of region
ExcludeEdge
Exclude edge of region
SizeFilter
Filter by size of region
DiameterFilter
Filter by diameter of region
RoundnessFilter
Filter by roundness of region
MeanIntensityFilter
Filter by mean intensity
※
of region
ROIFilter
Filter by location of region
※
Note
“MeanIntensity” in this procedure contains background (about 100). It is different
from
“MeanIntensity” output as measurement value.
④
Removal of Image Processing Method
Click “-“ button to remove methods. Within “Binarization” and
“Labeling” groups, at least one method has to be selected, thus
the last one method cannot be removed.
If a method specified as
“Input” for succeeding method is removed,
the
“Input” of its referenced method will become “Lost Reference”
and cause error. To correct such error, it is necessary to re-specify
“Input”.
⑤
Moving Image Processing Method
Image Processing Method can be moved up and down by clicking
“
▼
” or “
▲
” buttons at the right side. However, moving a method
above
“Input” specified method also results in “Lost Reference “.
Removed Method
Delete
Reference
Reference
Содержание CQ1
Страница 2: ...This document corresponds to the following versions of software Measurement software R1 04 ...
Страница 8: ...vi IM 80J01A01 01E Right Side of Utility Box Aperture label ...
Страница 24: ......
Страница 34: ......
Страница 48: ......
Страница 177: ... 5 Functions of CQ1 Software 5 81 IM 80J01A01 01E Drag tab to move the window ...
Страница 178: ...5 82 5 Functions of CQ1 Software IM 80J01A01 01E Drag tab to square mark as following to add the tab to the window ...
Страница 187: ... 5 Functions of CQ1 Software 5 91 IM 80J01A01 01E 4 Area Window Display image of Area by tile Change to Area from Field ...
Страница 236: ......
Страница 238: ......
Страница 252: ...7 14 7 Trouble Shooting IM 80J01A01 01E Set sub cover and tighten 2 screws ...
Страница 256: ......
Страница 266: ......