16-10
IM 765501-01E
Command
Function
Page
:ACTual?
Queries the actual number of stored points.
16-29
:CALCulate
:MINimum?
Queries the minimum value among the stored measured values.
16-29
:MAXimum?
Queries the maximum value among the stored measured values.
16-29
:AVERage?
Queries the average value among the stored measured values.
16-29
:SDEViation?
Queries the standard deviation of the stored measured values.
16-30
:DATA
:NUMBer <Integer>|MINimum|MAXimum|UP|DOWN
Sets the store data number.
16-30
:NUMBer? [MINimum|MAXimum]
Queries the store data number.
16-30
:TIME?
Queries the time stamp of the stored data.
16-30
:SOURce?
Queries the source value of the stored data.
16-30
[:SENSe]?
Queries the measured value of the stored data.
16-30
:SETup?
Queries the stored data setup mnemonic.
16-30
:MONLy 1|0|ON|OFF
Sets the measurement-only state (ON or OFF).
16-30
:MONLy?
Queries the measurement-only state (ON or OFF).
16-30
External Input/Output Commands (ROUTe Group)
:ROUTe
:BNCI
:SELect TRIGger|SWEep|CONTrol
Selects the BNC input (trigger input, sweep start input, or control input).
16-31
:SELect?
Queries the BNC input selection (trigger input, sweep start input,
or control input).
16-31
:CONTrol ILOCk|OUTPut|ZERO
Selects the BNC control input (interlock, output control, or zero control).
16-31
:CONTrol?
Queries the BNC control input selection (interlock, output control,
or zero control).
16-31
:BNCO
:SELect TRIGger|SWEep|CONTrol
Selects the BNC output (trigger output, sweep synchronization output,
or control output).
16-31
:SELect?
Queries the BNC output selection (trigger output, sweep synchronization output,
or control output).
16-31
:TRIGger ORIGin|SCHange|MBEGin|MEND|PEND
Sets the BNC trigger output generation timing (trigger, source change,
measurement begin, measurement end, or pulse end).
16-31
:TRIGger?
Queries the BNC trigger output generation timing (trigger, source change,
measurement begin, measurement end, or pulse end).
16-31
:SWEep ORIGin|TURN|ALL
Sets the BNC sweep synchronization output generation timing
(sweep start, 1 turn end, all sweep end).
16-31
:SWEep?
Queries the BNC sweep synchronization output generation timing
(sweep start, 1 turn end, all sweep end).
16-31
:CONTrol ILOCk|OUTPut|ZERO|PROGram
Selects the control output (interlock, output control, zero control,
or programmable).
16-32
:CONTrol?
Queries the control output selection (interlock, output control, zero control,
or programmable).
16-32
:DIO5 OUTPut|ZERO
Sets the function (output control or zero control) of pin 5 (control input)
of the external input/output connector.
16-32
:DIO5?
Queries the function (output control or zero control) of pin 5 (control input)
of the external input/output connector.
16-32
:DIO6 ORIGin|SCHange|MBEGin|MEND|PEND
Sets the function (trigger start point, source change, measurement begin,
measurement end, or pulse end) of pin 6 (trigger output) of the external
input/output connector.
16-32
16.2 Commands