16-6
IM 765501-01E
16.2 Commands
16.2.1 A List of Commands
Command
Function
Page
Output Commands (OUTPut Group)
:OUTPut
[:STATe] 1|0|ON|OFF|ZERO
Sets the output state (ON, OFF, or ZERO).
16-14
[:STATe]?
Queries the output state (ON, OFF, or ZERO).
16-14
:PROGram 1|0|ON|OFF|PULSe
Sets the programmable output state (ON or OFF) and executes pulse
generation.
16-14
:PROGram?
Queries the programmable output state (ON or OFF).
16-14
Source Commands (SOURce Group)
:SOURce
:FUNCtion VOLTage|CURRent
Sets the source function (voltage or current).
16-15
:FUNCtion?
Queries the source function (voltage or current).
16-15
:SHAPe DC|PULSe
Sets the source mode (DC or pulse).
16-15
:SHAPe?
Queries the source mode (DC or pulse).
16-15
:MODE FIXed|SWEep|LIST
Sets the source pattern (fixed level, sweep, or program sweep).
16-15
:MODE?
Queries the source pattern (fixed level, sweep, or program sweep).
16-15
:DELay <Time>|MINimum|MAXimum
Sets the source delay.
16-15
:DELay? [MINimum|MAXimum]
Queries the source delay.
16-15
:PULSe
:WIDTh <
Time
>|MINimum|MAXimum
Sets the pulse width when generating pulse signals.
16-15
:WIDTh? [MINimum|MAXimum]
Queries the pulse width when generating pulse signals.
16-15
:LIST
:SELect <String>
Sets the program sweep pattern file.
16-16
:SELect?
Queries the program sweep pattern file
16-16
:CATalog?
Queries the list of program sweep pattern files.
16-16
:DELete <String>
Deletes the program sweep pattern file.
16-16
:DEFine <String>,<String>
Creates a program sweep pattern file.
16-16
:VOLTage
:RANGe <Voltage>|MINimum|MAXimum|UP|DOWN
Sets the voltage source range setting (200 mV, 2 V, 12 V, 20 V, 30 V,
60 V, or 110 V).
16-16
:RANGe? [MINimum|MAXimum]
Queries the voltage source range setting (200 mV, 2 V, 12 V, 20 V, 30 V,
60 V, or 110 V).
16-16
:AUTO
<Boolean>
Sets the source auto range (ON or OFF).
16-16
:AUTO?
Queries the source auto range (ON or OFF).
16-16
:LEVel <Voltage>|MINimum|MAXimum
Sets the voltage source level value.
16-17
:LEVel?[MINimum|MAXimum]
Queries the voltage source level value.
16-17
:PBASe <Voltage>|MINimum|MAXimum
Sets the pulse base value for voltage pulse generation.
16-17
:PBASe? [MINimum|MAXimum]
Queries the pulse base value for voltage pulse generation.
16-17
:PROTection
[:STATe] 1|0|ON|OFF
Sets the limiter state (ON or OFF).
16-17
[:STATe]?
Queries the limiter state (ON or OFF).
16-17
:LINKage 1|0|ON|OFF
Sets the limiter tracking state (ON or OFF).
16-17
:LINKage?
Queries the limiter tracking state (ON or OFF).
16-17
:ULIMit <Voltage>|MINimum|MAXimum
Sets the upper voltage limiter value (for generating current).
16-17
:ULIMit? [MINimum|MAXimum]
Queries the upper voltage limiter value (for generating current).
16-17