Configuring Advanced Features
703
Details of Configuration Parameters:
Parameters
Permitted Values
Default
sip.min_udp_port
Integer from
1024 to 65535
50000
Description:
Configures the minimum UDP port.
Note: If you change this parameter, the IP phone will reboot to make the change
take effect.
Web User Interface:
Network->Advanced->UDP Port Scope
Phone User Interface:
None
sip.max_udp_port
Integer from
1024 to 65535
50249
Description:
Configures the maximum UDP port.
Note: The value of the maximum UDP port cannot be less than that of the minimum
UDP port. If you change this parameter, the IP phone will reboot to make the
change take effect.
Web User Interface:
Network->Advanced->UDP Port Scope
Phone User Interface:
None
sip.min_tcp_port
Integer from
1024 to 65535
50000
Description:
Configures the minimum TCP port.
Note: If you change this parameter, the IP phone will reboot to make the change
take effect.
Web User Interface:
Network->Advanced->TCP Port Scope
Phone User Interface:
None
sip.max_tcp_port
Integer from
1024 to 65535
50249
Содержание SIP-T2 Series
Страница 1: ......
Страница 14: ...Administrator s Guide for SIP T2 Series T19 P E2 T4 Series CP860 IP Phones xiv...
Страница 45: ...Getting Started 23 For SIP T42G T41P T40P Desk Mount Method Wall Mount Method Optional...
Страница 47: ...Getting Started 25 For SIP T23P T23G Desk Mount Method Wall Mount Method Optional...
Страница 122: ...Administrator s Guide for SIP T2 Series T19 P E2 T4 Series CP860 IP Phones 100...
Страница 504: ...Administrator s Guide for SIP T2 Series T19 P E2 T4 Series CP860 IP Phones 482...
Страница 757: ...Configuring Advanced Features 735 The IP phone reboots automatically to make settings effective after a period of time...
Страница 758: ...Administrator s Guide for SIP T2 Series T19 P E2 T4 Series CP860 IP Phones 736...
Страница 812: ...Administrator s Guide for SIP T2 Series T19 P E2 T4 Series CP860 IP Phones 790 6 Click Confirm to accept the change...
Страница 1005: ...Appendix 983...