5. Operating the Inverter
35
Operating the Digital Operator
All functions of the VS mini are set using the Digital Operator. Below
are descriptions of the display and keypad sections.
Digital Operator
Data display section
Press to enter the
constant data.
(Displays the constant
data when
selecting a constant No.
for PRGM indicator.)
Press to switch
between functions.
Press to increase
constant No./data value.
Press to decrease
constant No./data
value.
Press to stop the motor.
(Press to reset faults.)
Press to run the motor.
Frequency setting
potentiometer
Used to change
frequency setting.
Status indicators
Function indicators
Indicators switch to
another function each
time DSPL is pressed.
The displayed data can
be changed.
Details of Indicators (Color in parenthesis indicates the color of indicator.)
FREF
Frequency reference
setting/monitoring
(GREEN)
F/R
Operator RUN
command FWD/REV
selection
(GREEN)
FOUT
Output frequency
monitoring
(GREEN)
IOUT
Output current
monitoring
(GREEN)
LO/RE
LOCAL/REMOTE
Selection
(RED)
MNTR
Multi-function
monitoring
(GREEN)
PRGM
Constant No./data
(RED)