74
Initial Settings
• FREQUENCY AGREE Signal (setting=2)
11
Base blocked
Closed when the Inverter output
is OFF.
-
12
Operating mode
Closed when LOCAL is selected
for the LOCAL/REMOTE selec-
tion.
-
13
Inverter operation ready
Closed when an Inverter fault is
not detected, and operation is
ready.
-
14
Fault restart
Closed during fault retries.
-
15
UV
Closed when undervoltage is de-
tected.
-
16
Reverse run
Closed during reverse run.
-
17
Speed search
Closed when Inverter conducts a
speed search.
-
18
Data output from com-
munications
Operates multi-function output
terminal independently from In-
verter operation (by MEMOBUS
communications)
83
No.
Terminal
Initial Setting
n40
MA, MB
1 (operating)
Setting
Name
Description
Ref.
Detection width
±
2 Hz
Release Width
±
4 Hz
Output Frequency
FREQUENCY AGREE Signal