36
Description of Status Indicators
There are two status indicators on the middle right section of the face of
the VS mini. The combinations of these indicators indicate the status of
the Inverter (ON, flashing, and OFF). RUN indicator and status indica-
tor on
button have the same function.
The following table shows the relationship between the Inverter condi-
tions and the indicator on the RUN button of the Digital Operator as
well as the RUN and ALARM indicators on the face of the VS mini.
The indicators are lit, unlit or flashing reflecting the order of priority.
For details on how the status indicators function for Inverter faults, refer
to
Chapter 8. Fault Diagnosis
. If a fault occurs, the ALARM indicator
will light.
Priority
Digital
Operator
(Optional)
Face of
the VS mini
Conditions
RUN
RUN
ALARM
1
Power supply is shut down.
Until the Inverter become ready after the power is
turned ON.
2
Fault
3
Emergency stop (STOP command is sent from the
Digital Operator when the control circuit terminals
were used to operate the Inverter.)
Emergency stop (Emergency stop alarm is sent from
the control circuit terminal.)
Note: Indicators will be the same as with alarm
(stopped) occurring after the Inverter is stopped.
4
Emergency stop (Emergency stop fault is sent from
the control circuit terminal.)
Note: Indicators will be the same as with fault occur-
ring after the Inverter is stopped.
5
Alarm (Stopped)
6
Alarm (Operating)
The RUN command is carried out when the External
baseblock command using the multi-function contact
input terminal is issued.
7
Stopped (During baseblock)
8
Operating (Including the status that the Inverter is op-
erating at a frequency below the minimum output fre-
quency.)
During dynamic braking when starting.
9
During deceleration to a stop
During dynamic braking when stopping.
RUN
:ON
:Flashing (long flashing)
:Flashing
:OFF