88
Example: Writing Constants from EEPROM in Operator to Inverter
A setting range check and matching check for the written constants are
executed after the constants are written from the Digital Operator to the
Inverter. If a constant error is found, the written constants are discarded
and the constants stored before writing are restored.
When a setting range error is found, the constant No. where an error
occurs is indicated by flashing.
When an inconsistency in the settings is found,
(
: a number)
is indicated by flashing.
Explanation
Operator Display
• Enable the settings for
constants n01 to n79.
• Press DSPL to light
[PRGM].
• Press ENTER to display
the set value.
• Change the set value to 4
by pressing the
or
key.
• Press
ENTER.
(May be a different constant No.)
(Lit)
(May be a different set value.)
(Flashes)
(Lit for one second.)
↓
(The constant No. is displayed.)
• Execute
write-in
(COPY) using the Con-
stant Copy Function
Selection (n76).
• Change the constant No.
to n76 by pressing the
or
key.
• Press ENTER to display
the set value.
• Change the set value to
CPy by pressing the
or
key.
• Press
ENTER.
• Press DSPL or ENTER.
(Lit)
(Lit)
(Flashes while executing the
copy.)
↓
(End is displayed after the copy
has been completed.)
(The constant No. is displayed.)