![YASKAWA VIPA SLIO SDI Скачать руководство пользователя страница 108](http://html1.mh-extra.com/html/yaskawa/vipa-slio-sdi/vipa-slio-sdi_operating-manual_3224728108.webp)
3.11 Operation
DANGER!
During operation of the safety PLC, no changes to the system configura-
tion are allowed.
Therefore:
Before extending the system, removing individual system components
and changing the wiring, the PLC system is basically be set into a safe
state dependent on the application by professional personnel.
For the operation the ambient data, which are specified in the technical
data must be adhered to! Commissioning is only permitted after the accli-
mation of the System SLIO safety modules!
Instructions for the operation of System SLIO standard system components like power
supply, bus coupler, IO modules can be found in the according manual.
3.12 Maintenance
CAUTION!
Make sure by organizational measures that the interval for the repeat
inspection of all system components is kept.
safety - safety relevant parameters’ page 17
n
With the System SLIO safety module there is no repeat test possible for the user.
n
If you keep the prescribed environmental conditions (see technical data) the corre-
sponding safety module is maintenance-free.
n
If you determine or assume a defect on a safety module, please contact YASKAWA.
3.13 Repair
CAUTION!
Defective safety modules may only be repaired by the manufacturer.
A defective safety module cannot be repaired. Please contact YASKAWA for spare.
3.14 Diagnostics
The personnel, who works with the safety signal module, must be instructed in the safety
regulations and the operation of the module to correctly operate it. In particular the reac-
tion to error messages and states requires special knowledge which the operator must
have. In the following you will find information about disturbances and the resulting error
messages.
Instructions for operation
Requirements to the oper-
ating personnel
VIPA System SLIO
Deployment
Diagnostics
HB300 | SM-S | 02x-1SD10 | en | 20-02
108