Event ID
Description
DatID: Station not available
DatID: Station available
DatID: Input address
DatID: Output address
0xED23
EtherCAT: Time out while changing the master state to OP, after CPU has changed to RUN
OB: Operating mode
0: Configuration in operating condition RUN
1: STOP (update)
2: STOP (memory reset)
3: STOP (auto initialization)
4: STOP (internal)
5: STARTUP (cold start)
6: STARTUP (restart/warm start)
7: STARTUP (hot restart)
9: RUN
10: HALT
11: COUPLING
12: UPDATING
13: DEFECTIVE
14: Error search mode
15: De-energised
253: Process image release in STOP
254: Watchdog
255: Not set
ZINFO1: Master status
0: Undefined/Unkown
1: Init
2: PreOp
3: Bootstrap
4: SafeOp
8: Op
ZINFO2: EtherCAT configuration present
0: There is no EC configuration
1: There is an EC configuration
ZINFO3: DC in sync
0: Not in sync
1: In sync
0xED30
EtherCAT: Topology deviation
System 300S
+
System specific event IDs
HB140 | CPU | 315-4PN23 | en | 18-02
198