4.4 Drive Mode and Programming Mode
82
YASKAWA
SIEPYEULA5001C LA500 Technical Manual
4.4
Drive Mode and Programming Mode
The keypad display of this drive has two modes: Drive Mode and Programming Mode.
•
Drive Mode
Use this mode to operate the drive. These operations are available:
–
Monitor operation statuses (for example, output frequency, output current, and output voltage)
–
Set the parameters that you can change while the drive is operating (for example, d1-01 to d1-17). Refer to
for more information.
•
Programming Mode
Use this mode to set parameters. These operations are available:
–
Examine and set the parameters that are not at default settings (Verify Mode)
–
See and set the basic parameters necessary for the drive operation (Setup Mode)
–
See and set all parameters (Parameter Setting Mode)
–
Automatically set motor parameters (Auto-Tuning Mode)
gives information about the functions you can access when you push
/
.
Note:
Set
b1-08 [Run Command Select in PRG Mode]
to accept or reject the Run command from an external source when in Programming
Mode. Refer to
b1-08: Up/Down Command Select in PRG Mode on page 284
for more information.
Table 4.3 Overview of the Modes
Mode
LED Display
Description
Description
Ref.
Drive Mode
(Operation of
the motor and
monitoring of
operation
status)
Frequency
reference
display
You can set and monitor frequency references.
-
Monitor display The keypad shows
Ux-xx [Monitor]
.
-
Output voltage
display
You can monitor the output voltage reference.
Set
o1-01 [User Monitor Selection]
to change the item shown on this screen.
Output current
display
You can monitor the output current.
-
Output
frequency
display
You can monitor the frequency output from the drive.
-
Forward/reverse
selection
: Motor rotates in forward direction
: Motor rotates in reverse direction
Note:
For applications where the motor must not rotate in reverse direction (for example, for fans and
pumps), you can use
b1-04 [Reverse Operation Selection]
to prevent reverse rotation.
How to set reverse operation
-
Programming
Mode
(Parameter
Settings)
Auto-Tuning
Mode
The drive automatically calculates and sets the motor parameters.
Parameter
Setting Mode
You can see and set all parameters.
Setup Mode
You can see and set the basic parameters necessary for drive operation.
Verify Menu
You can examine and set the parameters that are not at default settings.
◆
Drive Mode
These operations are available in Drive Mode:
•
Operate and stop the drive
•
Show the drive status monitors (for example, frequency reference, output frequency, output current, and output
voltage)
•
Show the alarm content
Содержание LA500
Страница 2: ...This Page Intentionally Blank 2 YASKAWA SIEPYEULA5001C LA500 Technical Manual...
Страница 10: ...10 YASKAWA SIEPYEULA5001C LA500 Technical Manual...
Страница 18: ...i 3 Glossary 18 YASKAWA SIEPYEULA5001C LA500 Technical Manual...
Страница 24: ...1 2 Features and Advantages of Control Methods 24 YASKAWA SIEPYEULA5001C LA500 Technical Manual...
Страница 38: ...2 8 Install the Keypad in a Control Panel or Another Device 38 YASKAWA SIEPYEULA5001C LA500 Technical Manual...
Страница 74: ...3 14 Wiring Checklist 74 YASKAWA SIEPYEULA5001C LA500 Technical Manual...
Страница 134: ...5 5 EN81 20 Compliant Circuit with no Motor Contactor 134 YASKAWA SIEPYEULA5001C LA500 Technical Manual...
Страница 135: ...YASKAWA SIEPYEULA5001C LA500 Technical Manual 135 6 Network Communications 6 1 MEMOBUS Modbus Communications 136...
Страница 164: ...6 1 MEMOBUS Modbus Communications 164 YASKAWA SIEPYEULA5001C LA500 Technical Manual...
Страница 202: ...7 10 Troubleshooting Without Fault Display 202 YASKAWA SIEPYEULA5001C LA500 Technical Manual...
Страница 218: ...8 6 Storage Guidelines 218 YASKAWA SIEPYEULA5001C LA500 Technical Manual...
Страница 234: ...10 6 Peripheral Devices and Options 234 YASKAWA SIEPYEULA5001C LA500 Technical Manual...
Страница 375: ...YASKAWA SIEPYEULA5001C LA500 Technical Manual 375...