12.9 o: Keypad-Related Settings
348
YASKAWA
SIEPYEULA5001C LA500 Technical Manual
■
o1-01: User Monitor Selection
No.
(Hex.)
Name
Description
Default
(Range)
o1-01
(0500)
RUN
User Monitor Selection
Sets the
U monitor
for the Drive Mode. This parameter is only available with an LED keypad.
106
(104 - 830)
When the drive is in Drive Mode, push
on the keypad to cycle through this data: frequency reference →
rotational direction → output frequency → output current →
o1-01
selection.
Set the
x-xx
part of
Ux-xx
that is shown in the fifth position in Drive Mode. For example, to show
U1-05 [Motor
Speed]
, set
o1-01 = 105
.
Note:
The monitors that you can select are different for different control methods.
■
o1-02: Monitor Selection at Power-up
No.
(Hex.)
Name
Description
Default
(Range)
o1-02
(0501)
RUN
Expert
Monitor Selection at Power-
up
Sets the monitor item that the keypad screen shows after you energize the drive. Refer to
“
U:
Monitors
”
for information about the monitor items that the keypad screen can show. This
parameter is only available with an LED keypad.
1
(1 - 5)
1 : Frequency Reference (U1-01)
2 : Direction
3 : Output Frequency (U1-02)
4 : Output Current (U1-03)
5 : User Monitor (o1-01)
Shows the monitor item selected in
o1-01 [User Monitor Selection]
.
■
o1-03: Keypad Display Unit Selection
No.
(Hex.)
Name
Description
Default
(Range)
o1-03
(0502)
Keypad Display Unit
Selection
Sets the display units for the frequency reference and output frequency.
0
(0 - 3)
Note:
•
Select the setting unit of these parameters:
–
d1-01 to d1-08 [Reference 1 to 8]
–
U1-01 [Frequency Reference]
–
U1-02 [Output Frequency]
–
U1-05 [Motor Speed]
–
U1-16 [SFS Output Frequency]
–
U4-14 [PeakHold Output Freq]
•
For monitor 2, the setting value is always
0 [Hz Unit]
.
0 : 0.01 Hz units
1 : 0.01% units
The maximum output frequency is 100%.
2 : Revolutions Per Minute (RPM)
The drive uses the maximum output frequency and number of motor poles calculate this value automatically.
Note:
When you set
o1-03 = 2 [r/min]
, make sure that you set the number of motor poles in
E2-04 [Motor Pole Count]
.
3 : User Units
Uses
o1-10
and
o1-11
to set the unit of measure. The value of parameter
o1-10
is the value when you remove the
decimal point from the maximum output frequency. Parameter
o1-11
is to the number of digits after the decimal
point in the maximum output frequency.
To display a maximum output frequency of 100.00, set parameters to these values:
V/f
OLV
V/f
OLV
V/f
OLV
Содержание LA500
Страница 2: ...This Page Intentionally Blank 2 YASKAWA SIEPYEULA5001C LA500 Technical Manual...
Страница 10: ...10 YASKAWA SIEPYEULA5001C LA500 Technical Manual...
Страница 18: ...i 3 Glossary 18 YASKAWA SIEPYEULA5001C LA500 Technical Manual...
Страница 24: ...1 2 Features and Advantages of Control Methods 24 YASKAWA SIEPYEULA5001C LA500 Technical Manual...
Страница 38: ...2 8 Install the Keypad in a Control Panel or Another Device 38 YASKAWA SIEPYEULA5001C LA500 Technical Manual...
Страница 74: ...3 14 Wiring Checklist 74 YASKAWA SIEPYEULA5001C LA500 Technical Manual...
Страница 134: ...5 5 EN81 20 Compliant Circuit with no Motor Contactor 134 YASKAWA SIEPYEULA5001C LA500 Technical Manual...
Страница 135: ...YASKAWA SIEPYEULA5001C LA500 Technical Manual 135 6 Network Communications 6 1 MEMOBUS Modbus Communications 136...
Страница 164: ...6 1 MEMOBUS Modbus Communications 164 YASKAWA SIEPYEULA5001C LA500 Technical Manual...
Страница 202: ...7 10 Troubleshooting Without Fault Display 202 YASKAWA SIEPYEULA5001C LA500 Technical Manual...
Страница 218: ...8 6 Storage Guidelines 218 YASKAWA SIEPYEULA5001C LA500 Technical Manual...
Страница 234: ...10 6 Peripheral Devices and Options 234 YASKAWA SIEPYEULA5001C LA500 Technical Manual...
Страница 375: ...YASKAWA SIEPYEULA5001C LA500 Technical Manual 375...