6.1 MEMOBUS/Modbus Communications
YASKAWA
SIEPYEULA5001C LA500 Technical Manual
151
Register No.
(Hex.)
Description
0022
Fault Contents
bit 0
1: During data writing, during motor switching
bit 1
Reserved
bit 2
bit 3
1: Upper/Lower Limit Fault
bit 4
1: Data Integrity Fault
bit 5
1: During EEPROM writing
bit 6
0: EEPROM writing
1: Change data only on the RAM
Note:
Enabled when
H5-17 = 1 [ENTER Command Response @CPU BUSY = Write to RAM Only]
.
bit 7 - F
Reserved
0023
U1-01 [Frequency Reference]
Note:
o1-03 [Frequency Display Unit Selection]
sets the units.
0024
U1-02 [Output Frequency]
Note:
o1-03 [Frequency Display Unit Selection]
sets the units.
0025
U1-06 [Output Voltage Ref] (units: 0.1 V)
Note:
Use
H5-10 [Modbus Register 0025H Unit Sel]
to change the setting unit.
0026
U1-03 [Output Current] (units: 0.1 A)
0027
U1-08 [Output Power]
0028
U1-09 [Torque Reference]
0029
Fault Description 2
bit 0
Reserved
bit 1
GF [Ground Fault]
bit 2
PF [Input Phase Loss]
bit 3
LF [Output Phase Loss]
bit 4
rH [Braking Resistor Overheat]
bit 5
Reserved
bit 6
oH4 [Motor Overheat Fault (PTC Input)]
bit 7 - F
Reserved
002A
Minor Fault Description 1
bit 0 - 1
Reserved
bit 2
EF [FWD/REV Run Command Input Error]
bit 3
bb [Baseblock]
bit 4
oL3 [Overtorque 1]
bit 5
oH [Heatsink Overheat]
bit 6
ov [Overvoltage]
bit 7
Uv [Undervoltage]
bit 8
Reserved
bit 9
CE [Modbus Communication Error]
bit A
bUS [Option Communication Error]
bit B
UL3/UL4 [Undertorque Detection 1/2]
bit C
oH3 [Motor Overheat (PTC Input)]
bit D
FbL [PID Feedback Loss], FbH [Excessive PID Feedback]
bit E
Reserved
bit F
CALL [Serial Comm Transmission Error]
Содержание LA500
Страница 2: ...This Page Intentionally Blank 2 YASKAWA SIEPYEULA5001C LA500 Technical Manual...
Страница 10: ...10 YASKAWA SIEPYEULA5001C LA500 Technical Manual...
Страница 18: ...i 3 Glossary 18 YASKAWA SIEPYEULA5001C LA500 Technical Manual...
Страница 24: ...1 2 Features and Advantages of Control Methods 24 YASKAWA SIEPYEULA5001C LA500 Technical Manual...
Страница 38: ...2 8 Install the Keypad in a Control Panel or Another Device 38 YASKAWA SIEPYEULA5001C LA500 Technical Manual...
Страница 74: ...3 14 Wiring Checklist 74 YASKAWA SIEPYEULA5001C LA500 Technical Manual...
Страница 134: ...5 5 EN81 20 Compliant Circuit with no Motor Contactor 134 YASKAWA SIEPYEULA5001C LA500 Technical Manual...
Страница 135: ...YASKAWA SIEPYEULA5001C LA500 Technical Manual 135 6 Network Communications 6 1 MEMOBUS Modbus Communications 136...
Страница 164: ...6 1 MEMOBUS Modbus Communications 164 YASKAWA SIEPYEULA5001C LA500 Technical Manual...
Страница 202: ...7 10 Troubleshooting Without Fault Display 202 YASKAWA SIEPYEULA5001C LA500 Technical Manual...
Страница 218: ...8 6 Storage Guidelines 218 YASKAWA SIEPYEULA5001C LA500 Technical Manual...
Страница 234: ...10 6 Peripheral Devices and Options 234 YASKAWA SIEPYEULA5001C LA500 Technical Manual...
Страница 375: ...YASKAWA SIEPYEULA5001C LA500 Technical Manual 375...