4.11 Fine Tuning during Test Runs (Adjust the Control Function)
108
YASKAWA
SIEPYEULA5001C LA500 Technical Manual
Table 4.13 Parameters for Fine Tuning the Drive (
A1-02 = 2 [OLV]
)
Issue
Possible Solutions
Parameter
Default
Recommended
Setting
•
Unsatisfactory motor torque and speed
response
•
Hunting or oscillation at mid-range speeds
(10 Hz to 40 Hz)
•
To increase the speed of torque or speed
response, decrease the setting value in 0.05-
unit increments.
•
If hunting or oscillation occur, decrease the
setting value in 0.05-unit increments.
n2-01 [Automatic Freq
Regulator Gain]
1.00
0.50 to 2.00
•
To increase the speed of torque or speed
response, decrease the setting value in 10 ms
increments and examine the response.
•
If hunting or oscillation occur or if the load
inertia is too much, increase the setting value
in 50 ms increments and examine the
response.
Note:
Make sure that this parameter setting is:
n2-
02 ≤ n2-03 [Automatic Freq Regulator Time
2]
.
When you adjust
n2-02
, you must also
increase the
C4-02 [Torque Compensation
Delay Time]
value by the same ratio.
n2-02 [Automatic Freq
Regulator Time 1]
50 ms
50 ms to 2000 ms
•
Speed response is slow.
•
Speed is not stable.
•
If speed response is slow, decrease the setting
value in 10 ms increments.
•
If speed is not stable, increase the value in 10
ms increments.
C3-02 [Slip
Compensation Delay
Time]
200 ms
100 ms to 500 ms
Speed precision is unsatisfactory.
•
If speed is too slow, increase the setting value
in 0.1 unit increments.
•
If speed is too fast, decrease the setting value
in 0.1 unit increments.
C3-01 [Slip
Compensation Gain]
1.0
0.5 to 1.5
•
The volume of the motor excitation sound is
too high.
•
Hunting or oscillation at low speeds (10 Hz or
lower)
•
If the volume of the motor excitation sound is
too high, increase the carrier frequency.
•
If hunting or oscillation occur at low speeds,
decrease the carrier frequency.
C6-02 [Carrier
Frequency Selection]
3 (8 kHz)
1 to upper limit value
•
Torque at low speeds (10 Hz or lower) is not
sufficient. speed response is slow.
•
Speed response is slow.
•
Large initial vibration at start up.
•
If torque or speed response are slow, increase
the setting value.
•
If there is large initial vibration at start up,
decrease the setting value
Note:
If you set the value too high, the drive can
output a large torque reference although the
load is light.
E1-08 [Mid Point A
Voltage]
25.0 V
Default s/- 2 V
E1-10 [Minimum
Output Voltage]
5 V
*1
The default setting changes when the settings for
A1-02 [Control Method Selection]
and
o2-04 [Drive Model (KVA) Selection]
change.
*2
The default setting changes when the settings for
A1-02 [Control Method Selection]
and
E1-03 [V/f Pattern Selection]
change.
*3
Recommended settings are for 200 V class drives. Multiply the voltage by 2 for 400 V class drives.
Содержание LA500
Страница 2: ...This Page Intentionally Blank 2 YASKAWA SIEPYEULA5001C LA500 Technical Manual...
Страница 10: ...10 YASKAWA SIEPYEULA5001C LA500 Technical Manual...
Страница 18: ...i 3 Glossary 18 YASKAWA SIEPYEULA5001C LA500 Technical Manual...
Страница 24: ...1 2 Features and Advantages of Control Methods 24 YASKAWA SIEPYEULA5001C LA500 Technical Manual...
Страница 38: ...2 8 Install the Keypad in a Control Panel or Another Device 38 YASKAWA SIEPYEULA5001C LA500 Technical Manual...
Страница 74: ...3 14 Wiring Checklist 74 YASKAWA SIEPYEULA5001C LA500 Technical Manual...
Страница 134: ...5 5 EN81 20 Compliant Circuit with no Motor Contactor 134 YASKAWA SIEPYEULA5001C LA500 Technical Manual...
Страница 135: ...YASKAWA SIEPYEULA5001C LA500 Technical Manual 135 6 Network Communications 6 1 MEMOBUS Modbus Communications 136...
Страница 164: ...6 1 MEMOBUS Modbus Communications 164 YASKAWA SIEPYEULA5001C LA500 Technical Manual...
Страница 202: ...7 10 Troubleshooting Without Fault Display 202 YASKAWA SIEPYEULA5001C LA500 Technical Manual...
Страница 218: ...8 6 Storage Guidelines 218 YASKAWA SIEPYEULA5001C LA500 Technical Manual...
Страница 234: ...10 6 Peripheral Devices and Options 234 YASKAWA SIEPYEULA5001C LA500 Technical Manual...
Страница 375: ...YASKAWA SIEPYEULA5001C LA500 Technical Manual 375...