4.1 Two-step Trial Operation
4 -5
4.
Operate with Panel Operator.
SGDH-
MODE/SET
DATA/
CHARGE
POWER
SERVOPACK
200V
YASKAWA
Panel Operator
Operate the Servomotor using the Panel Operator. Check to see if the Servomotor runs nor-
mally.
See
6.2.2ControllingOperationThroughtheDigitalOperator
formore detailson theproce-
dure.
5.
Connect the signal lines.
Connect the
CN1 connector.
L1
L2
L3
U
V
W
L1C
L2C
B1
B2
B3
1
2
C
N
3
C
N
1
C
N
2
YASKAWA
SERVOPACK
MODE/SET
DATA/
CHARGE
POWER
SGDH-
200V
Use the following procedure to connect the CN1 connector.
a)
Turn OFF power.
b)
Connect the CN1 connector.
c)
Turn ON power again.
6.
Check the input signals.
Check input signal wiring in Monitor Mode using the Panel Operator. See
6.1.7 Operation
in Monitor Mode
for more details on the procedure.
Turn ONand OFFeach signal line to see if the LEDmonitor bit display on the panel changes
as shown below.
Input signal LED display
/P-CL
/N-CL
Top lights when OFF (high level).
Bottom lights when ON (low level).
/ALM-RST
/P-CON
/S-ON
P-OT
N-OT
SEN
4