Using the Digital Operator
7.2.2 Controlling Operation Through the Digital Operator
7 -22
7.2.2 Controlling Operation Through the Digital Operator
CAUTION
!
D
Forward run prohibited (P-OT) and reverse run prohibited (N-OT) signals are not effective during
jog operations using user constant Fn002.
Controlling operation through the Digital Operator allows the Servopack to run the motor. This
allows rapid checking of motor’srotation direction and speed setting during machine set-up and
testing, without the trouble of connecting a host controller.
For motor speed setting procedure, refer to
7.1.6 Operation in User Constant Setting Mode
and
5.3.2 Setting JOG Speed
.
C
N
3
C
N
1
L1C
L2C
B1
B2
U
V
W
L1
L2
1
2
C
N
2
SGDH-
MODE/SET
DATA/
CHARGE
POWER
SERVOPACK
200V
YASKAWA
Power
Servopack
Servomotor
Panel
Operator
The following conditions must be satisfied to perform JOG mode operation.
S
If the Servo-ON input signal (/S-ON) is ON, turn it OFF.
S
Release the Servo-ON signal mask if user constant Pn50A.1 is set to 7, and the Servo has been set to
always be ON.
Operation procedure using the Digital Operator is described on the following pages.
7
INFO
AUDIN - 7 bis rue de Tinqueux - 51100 Reims - France - Tel : 03.26.04.20.21 - Fax : 03.26.04.28.20 - Web : http: www.audin.fr - Email : [email protected]