5.2 Settings According to Host Controller
5 -33
3.
Set the soft start time.
Pn305
Soft Start Acceleration
Time
Unit:
ms
Setting
Range:
0 to 10000
Factory
Setting:
0
Speed Control
Pn306
Soft Start Deceleration
Time
Unit:
ms
Setting
Range:
0 to 10000
Factory
Setting:
0
Speed Control
TheServopackinternalspeedreferencecontrolsspeedby applyingthisaccelerationsetting.
Servopack
internal speed
reference
Speed
reference
Soft start
Maximum speed of Servomotor
Pn305: Sets this time interval.
Maximum speed of Servomotor
Pn306: Sets this time interval.
Smooth speed control can be performed by inputting a progressive speed reference or using
contact input speed control. Set each constant to 0 for normal speed control.
Set each user constant to the following time intervals.
·
Pn305: Time interval from when the Servomotor starts until it reaches maximum speed
of Servomotor.
·
Pn306: Time interval from when the Servomotor maximum speed until it stops.
J
J
Operation by Contact Input Speed Control
The following describes operation by contact input speed control.
Start and Stop
The following input signals are used to start and stop the Servomotor.
®
Input /P-CL CN1-45
Speed Selection 1
(Forward External Torque Limit
Input)
Speed/Torque
Control,
Position Control
®
Input /N-CL CN1-46
Speed Selection 2
(Reverse External Torque Limit
Input)
Speed/Torque
Control,
Position Control
5