User Constant Settings and Functions
5.8.1 Wiring Precautions
5 -108
Main Circuit
Power Supply
Current Capacity
per QF or Fuse
(A
rms
)
*1,*2
Power Capacity
per Servopack
(kVA)
*1
Applicable
Motor
Servopack Model
Main Circuit
Power Supply
Current Capacity
per QF or Fuse
(A
rms
)
*1,*2
Power Capacity
per Servopack
(kVA)
*1
Applicable
Motor
SGDH-
Capacity (kW)
Three-phase:
200 V
11.0
1AAE
SGMGH-1AA
22.7
60
Three-phase:
200 V
15.0
1EAE
SGMGH-1EA
30.9
81
Three-phase:
400 V
0.45
05DE
SGMGH-05D
1.1
1.6
Three-phase:
400 V
1.0
10DE
SGMGH-09D
1.0
10DE
SGMSH-10D
2.3
3.4
SGMUH-10D
2.3
3.4
1.5
15DE
SGMGH-13D
1.5
15DE
SGMSH-15D
3.2
4.6
SGMUH-15D
3.2
4.6
2.0
20DE
SGMGH-20D
4.9
7.1
2.0
20DE
SGMSH-20D
4.9
7.1
3.0
30DE
SGMGH-30D
3.0
30DE
SGMSH-30D
6.7
9.7
SGMUH-30D
6.7
9.7
5.0
50DE
SGMGH-44D
j
A
5.0
50DE
SGMSH-40D
j
A
10.3
14.9
SGMSH-50D
j
A
10.3
14.9
SGMUH-40D
j
A
6.0
60DE
SGMGH-55D
j
A
12.4
17.8
7.5
75DE
SGMGH-75D
j
A
15.4
22.3
11.0
1ADE
SGMGH-1AD
j
A
22.6
32.7
15.0
1EDE
SGMGH-1ED
j
A
30.9
44.6
* 1.
This is the net value at the rated load. When actually selecting fuses, determine the capacity using the prescribed
derating.
* 2.
Operating characteristics (at 25
°
C): 2 seconds or more for 200%, 0.01 second or more for 700%
Note
A fast-operating fuse cannot be used because the Servopack power supply is a capacitor input type. A fast-op-
erating fuse may blow out when the power is turned ON.
SGDH Servopacks do not have built-in ground protection circuits. To configure a safer system, install an earth
leakage breaker for protection again overloads and short-circuiting, or else install an earth leakage breaker for
ground protection in combination with a wiring circuit breaker.
5
IMPORTANT
AUDIN - 7 bis rue de Tinqueux - 51100 Reims - France - Tel : 03.26.04.20.21 - Fax : 03.26.04.28.20 - Web : http: www.audin.fr - Email : [email protected]