3.3 Main Circuit Wiring
3 -17
Fig. A
Fig. B
3.
Insert the wire core into the opening and then close the opening by releasing the lever or re-
moving the screwdriver.
J
J
Preparing the End of the Wire
Wire can be used simply by stripping back the outer coating. The following are applicable wire
sizes.
D
Single wire
Ø0.5 to Ø1.6 mm
. . . . . .
D
Braided wire
AWG28 to AWG12
. . . . .
The terminal block for Servopack SGDH-- DE for 400 V 50 W to 1.5 kW, has an indication “300 V, 15 A”.
This is a rating recognition of UL authorization, which means that the terminal blocks are authorized for “lim-
ited rating for industrial use” and applicable up to 600 V. Accordingly, these terminal blocks are applicable
for Servopack for 400V.