5.7 Absolute Encoders
5 -95
MODE
/
SET
DATA
/
Ver.
POWER
BATTERY
CN3
CN5
CN8
Battery carrying space
Batter connector (CN8)
SGDH
Figure 5.3
Servopacks with Capacities of 6.0 to 15 kW
PROHIBITED
D
Install the battery at either the host controller or the Servopack. It is dangerous to install batteries at
both simultaneously, because that sets up a loop circuit between the batteries.
5.7.4 Absolute Encoder Setup
Perform the setup operation for the absolute encoder in the following circumstances:
D
When starting the machine for the first time.
D
When an encoder backup alarm is generated.
D
When the Servopack’s power supply is turned OFF and the encoder’s cable is removed.
The setup operation can be performed by using the Hand-held Digital Operator or the Servo-
pack’s Panel Operator, or else personal computer monitor software can be employed.
The setup operation procedure shown here uses the Digital Operator. For more details, refer to
Chapter 6 Using the Digital Operator
.
The absolute encoder setup operation is only possible when the servo is OFF. After the setup processing is fin-
ished, turn the power back ON again.
J
J
Setup Using the Hand-held Digital Operator
1.
Press the DSPL/SET Key to select the auxiliary function mode.
2.
Select the user constant Fn008. Press the Left or Right Cursor Key to select the digit to set,
and then press the Up or Down Cursor Key to change the number.
3.
Press the DATA/ENTER Key. The following display will appear.
5
INFO
AUDIN - 7 bis rue de Tinqueux - 51100 Reims - France - Tel : 03.26.04.20.21 - Fax : 03.26.04.28.20 - Web : http: www.audin.fr - Email : [email protected]