No.
Name
Display
Content
8
FWD/REV
FWD
Indicates forward motor operation.
REV
Indicates reverse motor operation.
9
Function Key 1
(F1)
<-MONITOR->
Pressing
F1
displays the next Quick Monitor.
←
Pressing
F1
scrolls the cursor to the left.
Home
Pressing
F1
returns to the top menu (Frequency Reference).
ESC
Pressing
F1
returns to the previous display.
Monitor
Pressing
F1
switches Monitor mode.
<1> Displayed when in Frequency Reference Mode.
<2> Displayed when in Frequency Reference Mode and Monitor Mode.
u
ALARM (ALM) LED Displays
Table i.19 ALARM (ALM) LED Status and Contents
State
Content
Display
Illuminated
When the drive detects an alarm or error.
Flashing
• When an alarm occurs.
• When an oPE is detected.
• When a fault or error occurs during Auto-Tuning.
Off
Normal operation (no fault or alarm).
i.5 Start-Up Programming and Operation