CIMR -
P W 2
A
0021
F
A A
Drive
P1000
Series
No. Enclosure Type <1>
Design
Revision
Order
No.
Customized
Specifications
A Standard model
IP00/Open Type
F
A
No.
Environmental
Specification <3>
A
Standard
Refer to the tables below
No.
Region
Code
Water
W
No.
Voltage Class
3-phase, 380-480 Vac
3-phase, 200-240 Vac
2
4
3-phase, 500-600 Vac
5
U
Flange Type <2>
IP20/NEMA 1,
UL Type 1
<1>
for differences regarding enclosure protection types and component descriptions.
<2> Provides method of mounting drive with backside (heatsink) external to enclosure, with NEMA 12 integrity.
<3> Please contact Yaskawa for details regarding Environmental Specifications.
n
Three-Phase 200 V Class
Drive Model
Max. Motor Capacity kW (HP)
Rated Output Current A
2A0004
0.75 (0.75)
3.5
2A0006
1.1 (1)
6.0
2A0008
1.5 (2)
8.0
2A0010
2.2 (3)
9.6
2A0012
3.0 (3)
12
2A0018
3.7 (5)
17.5
2A0021
5.5 (7.5)
21
2A0030
7.5 (10)
30
2A0040
11 (15)
40
2A0056
15 (20)
56
2A0069
18.5 (25)
69
2A0081
22 (30)
81
2A0110
30 (40)
110
2A0138
37 (50)
138
2A0169
45 (60)
169
2A0211
55 (75)
211
2A0250
75 (100)
250
2A0312
90 (125)
312
2A0360
110 (150)
360
2A0415
110 (175)
415
i.2 Receiving
12
YASKAWA TOEP YAIP1W 02E YASKAWA AC Drive - iQpump1000 Installation & Start-up Guide