E7 Drive Parameters 4-18
Prm
Adr
Function
Data
Limits / Selections
Inc
Default
Run Acs
Dep
L6-01 04A1h
Torq Det 1 Sel
0 Disabled
1 0
A
o2-09*
1 OL@SpdAgree-Alm
2
OL At RUN - Alm
3 OL@SpdAgree-Flt
4
OL At RUN - Flt
5 UL@SpdAgree-Alm
6
UL At RUN - Alm
7 UL@SpdAgree-Flt
8
UL At RUN - Flt
L6-02 04A2h
Torq Det 1 Lvl
0 ~ 300 %
1% 15%
A
L6-03 04A3h Torq Det 1 Time
0.0 ~ 10.0 Sec
0.1 Sec
10.0 Sec
A
L8-01 04ADh DB Resistor Prot
0
Not Provided
1
0
F
1
Provided
L8-02 04AEh OH Pre-Alarm Lvl
50 ~ 130 Deg
1 Deg
95 Deg
A kVA*
L8-03 04AFh OH Pre-Alarm Sel
0
Ramp to Stop
1 4
A
1 Coast
to
Stop
2 Fast-Stop
3 Alarm
Only
4 OH
Alarm&Reduce
L8-04 04B0h OH1 Fault Level
50 ~ 130 Deg
1 Deg
105 Deg
F
kVA*
L8-05 04B1h
Ph Loss In Sel
0
Disabled
1
1
F o2-09*
1
Enabled
L8-06 04B2h
Ph Loss In Lvl
0.0 ~ 25.0 %
0.10% 7.50%
A kVA*
L8-07 04B3h
Ph Loss Out Sel
0
Disabled
1
1
F o2-09*
1
Enabled
L8-08 04B4h
Ph Loss Out Lvl
0.0 ~ 20.0 %
0.10%
5.00%
F
L8-09 04B5h Ground Fault Sel
0 Disabled
1 1
A
1 Enabled
L8-10 04B6h
Fan On/Off Sel
0
Fan On-Run Mode
1 0
A
1
Fan Always On
L8-11 04B7h
Fan Delay Time
0 Disabled
1 Sec
300 Sec
A
1 Enabled
L8-12 04B8h
Ambient Temp
45 ~ 60 Deg
1 Deg
45 Deg
A
L8-13 04B9h
UV3 Detect
0
Disabled
1
1
F
1
Enabled
L8-14 04BAh
Inverter OL Sel
0
Disabled
1
0
F
1
Enabled
L8-15 04BBh OL2 Sel @ L-Spd
0 Disabled
L8-16 must be set to enable this parameter
1
1
A L8-16
1 Enabled
L8-16 04BCh Low Spd OL2 Freq
0
Disabled
0.1 Hz
0.1 Hz
F
1
Enabled
L8-17 04BDh
OL2 0Hz Gain
0
Disabled
1%
60%
F
1
Enabled
L8-18 04BEh
Soft CLA Sel
0 Disabled
1 1
A
1 Enabled
L8-19 04BFh
Fref During OH
0.0 ~ 100.0 %
0.10% 20.00%
A
n1-01 0580h
Hunt Prev Select
0 Disabled
1 1
A
1 Enabled
n1-02 0581h
Hunt Prev Gain
0.0 ~ 2.5
0.01 1
A
n1-03 0582h
Hunt Prev Time
0 ~ 500 ms
1 ms
10 ms
F
kVA*
n1-04 0583h
Hunt Prev Limit
0 ~ 100 %
1%
5%
F
n3-01 0588h HSB Decel Width
1 ~ 20 %
1% 5%
A
n3-02 0589h HSB Current Ref
100 ~ 200 %
1% 150%
A
n3-03 058Ah HSB DwelTim@Stp
0.0 ~ 10.0 Sec
0.1 Sec
1.0 Sec
A
n3-04 058Bh
HSB OL Time
30 ~ 1200 Sec
1 Sec
40 Sec
A
n3-05 058Ch
HSB V/F Gain
1 ~ 50 %
1%
5%
F
n3-06 058Dh Spd Agr Current
0 ~ 100 %
1%
50%
F
n3-07 058Eh
Spd Agree Time
100 ~ 2000 ms
1 ms
800 ms
F
n3-08 058Fh
HSB V Lvl1
80 ~ 90 %
1%
87%
F
n3-09 0590h
HSB V Lvl2
90 ~ 95 %
1%
92%
F
n3-10 0591h HSB RI Comp Coef
20 ~ 100 %
1%
50%
F
n3-11 0592h HSB RI Comp Tim
10 ~ 1000 ms
1 ms
200 ms
F
n3-12 0593h Prohib HSB Decel
0 ~ 20 Hz
1 Hz
6 Hz
F
n9-01 05D0h Inv Rate Current
0.0 ~ 1500.0 A
0.1 A
0.0 A
F
kVA*
n9-02 05D1h
DCCT Gain
0.0 ~ 2.0
0.001
0
F
kVA*
n9-09 05D8h
AVR Selection
0
Disabled
1
1
F
1
Enabled
2
Stabilize
n9-10 05D9h
AVR Time
0.0 ~ 100.0 ms
0.1 ms
1.0 ms
F
n9-11 05DAh ON-Delay Time
2.5 ~ 18.0 us
0.1 us
3.0 us
F
kVA*
n9-12 05DBh ON-Delay Comp
0.0 ~ 20.0 us
0.1 us
3.0 us
F
kVA*
n9-13 05DCh IGBT Volt Drop
0.0 ~ 10.0 VDC
0.1 VDC
0.0 VDC
F
n9-14 05DDh Pwr Angle Filt 1
0 ~ 1000 ms
1 ms
5 ms
F
kVA*
n9-15 05DEh Pwr Angle Filt 2
0 ~ 1000 ms
1 ms
5 ms
F
n9-19 05E2h DCCT Filter Time
-1000 ~ 1000 us
1 us
0 us
F
Содержание CIMR-E7U Series
Страница 1: ...E7 Drive Parameter Access Technical Manual Drive Models CIMR E7U Document Number TM E7 11...
Страница 2: ......
Страница 6: ...iv This page intentionally left blank...
Страница 8: ...Connections 1 2 This page intentionally left blank...
Страница 10: ...Connections 1 4 This page intentionally left blank...
Страница 19: ...Connections 1 13 This page intentionally left blank...
Страница 21: ...Message Formats 2 2 This page intentionally left blank...
Страница 35: ...Troubleshooting 3 2 This page intentionally left blank...
Страница 43: ...Troubleshooting 3 10 This page intentionally left blank...
Страница 45: ...E7 Drive Parameters 4 2 This page intentionally left blank...
Страница 71: ...E7 Drive Parameters 4 28 This page intentionally left blank...
Страница 73: ...User Notes 5 3 This page intentionally left blank...
Страница 81: ...User Notes 5 11 Notes Enter the current application parameter data and any relevant notes...