![YASKAWA ArcWorld 50 Скачать руководство пользователя страница 79](http://html1.mh-extra.com/html/yaskawa/arcworld-50/arcworld-50_system-manual_3245409079.webp)
3-15
183574-1CD
183574-1CD
3
Installation
3.6 Safety/Operation Check
ArcWorld 50/50S/52/52S
3.6 Safety/Operation Check
Before installing the tooling and fixtures for the application, take a few
minutes to perform the following safety/operation check:
1. Ensure that all shipping brackets and material are removed from the
system.
2. Check the security and integrity of all cable connections.
3. Ensure that the work-cell sliding access doors close and the door
interlocks engage properly.
4. Verify the correct settings for the welding power source (refer to the
welding power source documentation that is included with the
ArcWorld).
5. Verify that local electrical service complies with the power
requirements for the ArcWorld system.
6. Verify that local electrical service is correctly wired into the Controller
assembly and the welding power source (refer to
).
7. Rotate the Controller main power switch to ON (see
).
8. Check for correct operation of all EMERGENCY STOP buttons (refer
to
).
9. Check for correct operation of the system HOLD button on the
Programming Pendant. Refer to the
Operator's Manual for Arc
Welding
for more information on the pendant’s HOLD button
).
10. Check for correct action of the work-cell access door safety interlock.
11. Turn the Controller main power switch to OFF after completion of the
safety/operation check.
CAUTION
• Only qualified, trained personnel who are familiar with the ArcWorld
should perform the power-up sequence.
Failure to comply with this CAUTION may result in injury to personnel
and damage to equipment.
WARNING
• Before operating the Robot, verify that each EMERGENCY STOP
button disables servo power when activated (pushed in).
– Each EMERGENCY STOP button must immediately stop
the Robot and Positioner movement when activated.
If any of the EMERGENCY STOP buttons do not work correctly death
or serious injury may occur.
79 of 126